Fields
Template:
DRMS Permit Index
Permit No
C1982055
IBM Index Class Name
Enforcement
Doc Date
6/1/1993
Doc Name
ENERGY FUELS MINING CO RATON CREEK MINE PN C-82-055 ABATEMENT RESPONSE PART II FOR NOV C-93-52
From
ACZ INC
To
MLR
Violation No.
CV1993052
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENERGY FUELS MINING COMPANY <br />BATON CREEK MINES <br />NOV ABATEMENT RESPONSES (PART II) <br />MAY 1993 <br />NOV C-93-48 - Failure to obtain approval, prior to construction, of certain structures found <br />on-site. <br />Abatement Srep 9 • Submit a 7R for the existing powerline light use road as identifted in TR•06 <br />Response: Field surveys of the subject road and intersecting ditch indicate that the high point <br />of the road effectively segregates both ditch flow and drainage from the upper part of the road <br />from the refuse pile area. The only ponion of the road which could possibly drain to the refuse <br />pile is the lower 50 feet of the road. Limited road slope and some natural vegetative <br />reestablishment combine to limit potential runoff effetts. A technical revision for this road is <br />not necessary since the road is shown on existing permit maps and was discussed in the permit <br />text (refer to page 425) in conjunction with TR-06 submitted in April 1990. <br />NOV C-93-52 -Failure to properly install sections of approved upland diversions. <br />Abatement Steps 1-3 - 1) Install approved section of diversion, and, 2) Reconstruct portion of <br />diversion to drain into permanent watershed diversion as approved, or, 3) Submit a technical <br />revision to redesign diversions around substation area to reflect existing site conditions and provide <br />a revised Map 11 ro show southern diversion location and sections relative to approved designs, as <br />done for northern diversion. <br />Res~nse: Field inspection, and review of existing drainage designs have resulted in redesign <br />of the overall drainage configuration for this area to more effectively address both disturbed and <br />undisturbed area drainage within the constraints of actual site configuration. <br />Design information for existing Watershed Diversion 3 was found to be incomplete az presented <br />in the permit application document. Design information for this diversion has been expanded <br />to address applicable design requirements. Two new diversion/collection ditches, Watershed <br />Diversion 4 and Yard Area Ditch 2, have been added and corresponding hydrologic and <br />hydraulic designs have been completed. The new or revised ditch design information <br />accompanies these responses for insertion or replacement in the permit application document. <br />The revised drainage configuration for the subject area is shown on the draft of Map 12, <br />previously submitted with the abatement responses for NOV's C-93-46 and C-93-48 in early <br />May. Following OMLR review and comment, Map 12 will be revised if necessary and a final <br />certified map will be submitted consistent with the corresponding abatement date of June 25, <br />1993. <br />n:vserxos.tur <br />OS/U/9) Jpm <br />
The URL can be used to link to this page
Your browser does not support the video tag.