My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV11693
DRMS
>
Back File Migration
>
Revision
>
REV11693
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 1:22:39 AM
Creation date
11/21/2007 10:25:23 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981010
IBM Index Class Name
Revision
Doc Date
6/11/1987
Doc Name
TR 34 C-81-010 TRAPPER MINING INC
From
MLRD
To
GREGG SQUIRE
Type & Sequence
TR37
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • -iiiiiiiiiiiiiiiiiii <br />STATE OF COLORf ~~ <br />Roy Romer, Governor <br />DEPARTMENT OFNATURALRESOURCES <br />MINED LAND RECLAMATION DIVISION <br />DAVID C. SHELTON, Director <br />DATE: June 11, 1987 <br />T0: Gregg Squire <br />FROM: Candy Thompson <br />RE: Technical Revision #TR-34, C-81-010, Trapper Mining, Inc. <br />I have reviewed the above referenced, Technical Revision and have identified <br />the following inadequacies in the submittal. This information will need to be <br />submitted prior to Division approval. <br />Johnson Gulch Pond <br />The Johnson Gulch Pond configuration is presently approved as shown in <br />technical revision #25, submitted by Trapper mining on August 13, 1986. While <br />comparing the sediment input between the two revisions it was noted that <br />subwatershed 1,1,1 has a different acreage, curve number, and time of <br />concentration than the previously submitted data in #PR-25. The summary table <br />to precede the sediment run must be submitted for this watershed as was <br />submitted with watershed 3,1,3. <br />Spillway Design <br />The V-shape principal spillway is an acceptable design. However, the flat <br />portions of the emergency spillway and the sloping portions of the emergency <br />spillway across the dam embankment show no protection from erosion. Trapper <br />must submit calculations showing that allowable velocities for the emergency <br />spillway bed material will not be exceeded during a 25-year event or provide <br />for appropriate lining as required by Rule 4.05.6(3)(d). The ditch sizing <br />leading from the spillway must also be provided, demonstrating adequate <br />capacity and freeboard to carry the 25-year flow. <br />sak <br />0304E <br />423 Centennial Building, 1313 Sherman Street Denver, Colorado 80203-2273 Tel. (303) 866-3567 <br />
The URL can be used to link to this page
Your browser does not support the video tag.