—1' MIN 1' MIN. 1' MIN. <br />40 MIL SMOOTH LLDPE <br />GEOMEMBRANE <br />3" DIA. PCPE PIPE ON 1 <br />MIN. GRADE TO SUMP <br />3" DIA. SOLID CPE PIPE <br />3" DIA. SPLIT <br />Z LEAK DETECTION TRENCH <br />16 NOT TO SCALE <br />3" DIA. PCPE <br />TYPICAL SOLID TO PERFORATED <br />3 PCPE PIPE CONNECTION <br />16 NOT TO SCALE <br />STAKED AND ENTRENCHED 50 LB <br />(APPROXIMATE) STRAW BALE <br />COMPACTED SOIL TO <br />PREVENT PIPING— <br />SEDIMENT LADEN RUNOFF <br />i <br />1 " X 2" WOOD STAKE <br />TWINE /WIRE <br />i- FILTERED SEEPAGE <br />4 INCHES MIN. <br />6 INCHES MIN. <br />STRAW BALE INSTALLATION DETAIL <br />NOT TO SCALE <br />3 EACH METAL PIPE BOLLARDS <br />(MIN. 4" DIA.) EMBEDDED IN AND FILLED <br />WITH CONCRETE <br />e <br />CONCRETE <br />FOOTING — <br />(NOTE 1) <br />(NOTE 2) <br />2 <br />16 <br />PRE — FABRICATED ADS <br />MANHOLE WITH COVER <br />CONSISTING OF UPPER <br />UNIT AND BASE <br />GEOMEMBRANE <br />ANCHOR TRENCH <br />INSERT PIPE <br />INTO MANHOLE <br />2' MIN. DRAIN COVER FILL <br />PHASE IV <br />80 MIL TEXTURED <br />(TEXTURE FACE DOWN) <br />LLDPE GEOMEMBRANE <br />LEAK DETECTION <br />FILL <br />�. r •. �a;°r <br />s, „e a e� e�e', °y.e._w.;s -,e <br />b�e. <br />:L- e. <br />!P sb�YAa <br />�� <br />vYYrlt. <br />: .4+ ..e'a.. <br />�`�: °�r4 �'�:Y�,�O <br />.° iV3 .YO' °•e.r <br />e'e <br />°e. <br />� <br />+'E.a.',n�e:.�a� <br />.6�e:v.'. •�a'. >•.C- °•sir. ° : <br />I <br />s. a <br />.• <br /><�✓0 060 ,a .e <br />.b.,. <br />II I11 <br />+e, <br />° ... <br />•.4.b.} <br />.. O, I�III <br />IIII <br />INCREASE DEPTH OF LEAK <br />16 3" DIA. PCPE PIPE DETECTION TRENCH TO 24" <br />3" DIA. SOLID CPE PIPE FOR ANCHOR TRENCH <br />NOTES: <br />1. MANHOLE WITH LADDER ACCESS ALONG ENTIRE DEPTH <br />OF MANHOLE. <br />2. MINIMUM STORAGE VOLUME OF 100 GALLONS BELOW <br />3' DIA. SOLID CPE PIPE INLET. <br />LEAK DETECTION SUI,*4P DETAIL <br />NOT TO SCALE <br />I� fFILTER FABRIC MATERIAL SECURELY <br />FASTENED TO THE POSTS <br />WOOD OR <br />2' STEEL POST I' APPROXIMATELY 8" OF FILTER <br />(MIN.) l FABRIC MATERIAL MUST EXTEND INTO <br />TRENCH AND BE ANCHORED WITH <br />COMPACTED BACKFILL MATERIAL <br />¢ LOW <br />10" <br />APPROXIMATE 4 "x4" TRENCH <br />(MIN.) v %�� o:. <!.v/ ✓vZ <br />+ a <br />NOTES: "1A} ,') :1 20PU <br />NOTE 1. SPACE POSTS 6' TO 10' APART. <br />1. STRAW BALES TO EXTEND FAR ENOUGH LATERALLY 2. FOR ADDITIONAL STRENGTH, FILTER FABRIC MATERIAL <br />SO SURFACE WATER RUNOFF WILL SPILL OVER TOP OF STRAW MATERIAL CAN BE ATTACHED TO A 6" MESH WIRE <br />BALES. WHICH HAS BEEN FASTENED TO THE POSTS. <br />5 STRAW [SALE EXTENT DETAIL Q SILT FENCE INSTALLATION DETAIL <br />16 NOT TO SCALE 16 NOT TO SCALE <br />Permit # M- 1980 -244 <br />r <br />Amendement No. 8 March 81, 2000 <br />CC Crl.-4Mc Creslc C Victor Gold r.Wag Conncny <br />`T Crcccon Projcct <br />A Joint Venture — AngloGold (Colorado) Corp., Mona - <br />Tmx IlGiilillilllliillilllllllllll <br />PHASE [V 19519 <br />LEAK DETECTION AND EROSION CO.%ffROv DrETArLS <br />