My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ENFORCE21661
DRMS
>
Back File Migration
>
Enforcement
>
ENFORCE21661
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 7:31:41 PM
Creation date
11/21/2007 10:01:01 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981013
IBM Index Class Name
Enforcement
Doc Name
WRIGHT WATER ENGINEERS EXHIBIT A-U
Violation No.
CV2000009
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PN: 94-129 <br />March 24, 1994 <br />Page 3 <br />DR~-FT <br />The adobe structure is very old. The exterior finishing with stucco is common in some areas <br />but this does not allow the structure to breath and relieve itself of unwanted moisture to <br />maintain stable conditions. The cracking of the stucco allows moisture to penetrate into the <br />adobe that causes this moisture to freeze and thaw. This causes minor stresses that over time <br />add up to result in slow deterioration of the structural materials. <br />The existing conditions appear to be the result of the east wall settling and the east foundation <br />possible rotating resulting in the east wall to rotate outward. Since the main load carrying <br />elements are the logs and these span in the east-west direction in the den area, the load transfer <br />still is maintained. Moisture intrusion from the roof leaks both at the chimney, decking and <br />scuppers have contributed to this distress. Additional conditions such as the rotting of the tree <br />root system, poor drainage, boiler system water loss, and routine maintenance should be further <br />investigated. <br />Due to the lack of spanning capabilities for the foundation materials and the adobe construction, <br />the existing conditions should be stabilized in the present position. Additional exploratory work <br />should be made on the soils and foundation conditions along the east and portion of the south <br />and north foundation walls. Before any attempt to expose these foundations, the east wall <br />should be laterally shored to prevent further outward movemenc. <br />Until these conditions are known a complete design repair scope could not be prepared. <br />It is the opinion of this engineer that the distress is localized to the east portion and the major <br />contributing factors are the lack of maintenance, poor drainage and general aging. <br />
The URL can be used to link to this page
Your browser does not support the video tag.