My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004-10-07_REVISION - M1999002
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1999002
>
2004-10-07_REVISION - M1999002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 6:21:15 PM
Creation date
11/21/2007 9:45:47 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1999002
IBM Index Class Name
Revision
Doc Date
10/7/2004
Doc Name
Note on TR-04 Submittal
From
DMG
To
File
Type & Sequence
TR4
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit #: M• 1444-Z~Z Confidental?: <br />Class~'(12.~ Type-Seq.: <br />From: To: <br />TR-04 Comments: Doc. Name: tAn "fl2 •(~(• <br />Doc. Date (if no date stamp): I O - ~.0~ <br />Comments reQardin~ Appendix B; OualitV Permit Coudition Values <br />Potassium <br />We1121-3U (NPL) for K established at 64 mg/L. Value derived from one baseline sample <br />considerably higher than other baseline samples (others are less than 40 mg/L) and during <br />production (less than 20 mg/L). In the case of We1121-2, the highest baseline value was not <br />used as the EWI. <br />Would values that fall above the established NPL be a violation? <br />Silica <br />We1120-8 for Silica, listed as "report" rather than a permit condition value. The baseline values <br />(less than 30 mg/L) are much lower than production values (over 40 mg/L). <br />Total Dissolved Solids <br />Well 21-3A (NPL) one high baseline sample of 34,700 mg/L for TDS used to establish the NPL <br />at the point of compliance, but remaining values of baseline and after production fall around <br />20,000 mg/L. <br />Fluoride <br />We1121-3A (NPL) one high baseline sample of 56 mg(L fluoride used to establish the NPL at the <br />point of compliance, but most values of baseline and during production are less than 40 mg/L. <br />We1121-3B (NPL) two baseline readings above 75 mg/L fluoride, but remaining values from <br />baseline and production fall below 50 mg/L. <br />Possible exceedances with new NPL and EWI standards: <br />American Soda proposes new NPL and EWI standards for a number of water quality permit <br />condition values. Based on the new standards proposed, American Soda may exceed a number <br />of the newly established standards based on what they have sampled to date. The following is a <br />list of wells that will fall above the newly established NPL or EWI for the given standard: <br />Conductivity: <br />• 28-1 (EWI) <br />• 21-5 (EWI) <br />• 21-3U tNPL) <br />• 29-3 (EWI) <br />• 21-4a (EWI) <br />• 21-3b (NPL) <br />Potassium: <br />• 28-1 (EWI) <br />• 21-5 (EWI) <br />
The URL can be used to link to this page
Your browser does not support the video tag.