Laserfiche WebLink
<br />page 15. In addition, operator indicated that the upper road culvert in place was a <br />48" diameter cmp as specified in Appendix M documentation rather than 42" <br />diameter as depicted on Figure 3.1-4, and that Figure 3.1-4 will be revised <br />accordingly, <br />The Division will conduct field checks to verify the upper culvert 48" diameter, and <br />also to confirm adequate fill protection at the inlet and outlet of the 72" Munger <br />Creek culvert. Assuming no problems are identified based on the field check, the <br />item is resolved with the exception of the amended Figure 3.1-4. <br />Please suhmit a properly amended Figure 3.1-4. <br />54. Appendix M(vi) (Munger Canyon Sedimentation Reservoir) was properly deleted from <br />the application. Item resolved. <br />55. Portions of Appendix M(vii) that address hydrology design information for the Loma <br />Loadout Sediment Pond have been properly deleted from the application. Item <br />resolved. <br />56. Requested design specifications and documentation for temporary ephemeral <br />channel diversion Ditch H were submitted in amended page M(viii)-4viii, and the <br />ditch location is shown on amended Figure 2.2-4. Item resolved. <br />57. The operator has properly requested that permit volumes VI and VII be withdrawn <br />from the permit. These volumes contain information that is duplicative or no longer <br />applicable, The operator notes that, upon approval of the revision, the permit <br />application will consist of three volumes, Volume I will contain all text and tables, <br />Volume II will contain all figures and Volume III will contain all appendices. Item <br />resolved. <br />9-11-03 TR-16 PAR.doc <br />8 <br />