Laserfiche WebLink
<br /> <br />INCLINOMETER WELL REPORT B L <br />-102A <br /> , <br />Project Bruce Park Dam <br />Location Paonia Colorado PG. 1 OF 1 <br />Client Terror Ditch antl Reservoir Company Boring No. BL-102A <br />Contractor Heliport Dolling Driller Ron Lancaster Location Paonia <br />Observed by ERF Date Started 11.29-01 COlOfadO <br />Checked by RJH Date Completed 11.29-07 Project No. 99292 <br /> <br />SURVEY LENGTH OF COAXIAL CABLE ABOVE GROUND 6.0 <br />DATUM NGVD SURFACE (FT) <br /> LENGTH OF RISER PIPE A80VE GROUND 1.0 <br />GROUND SURFACE (FT) <br />ELEVATI ON <br /> THICKNESS OF SURFACE SEAL BELOW <br /> GROUND SURFACE, IF ANY (FT) <br /> TYPE OF SURFACE SEAL (indicate any <br /> additional seals) <br /> ID OF SURFACE CASING (IN) <br /> TYPE OF SURFACE CASING <br /> DEPTH BOTTOM OF CASING (FT) <br />~ ID and OD OF RISER PIPE (IN) 0.8 <br />to TYPE OF RISER PIPE Flush joint PVC <br />0 <br />o I ~ DIAMETER OF BOREHOLE (IN) 3.8 <br />Z <br />!/J <br />Z <br />O <br />H <br />~ <br />Z TYPE OF BACKFILL AROUND RISER PIPE Portland Cement <br />O <br />U <br />J <br />O DEPTH BOTTOM OF PVC RISER PIPE 19.0 <br /> I <br />Q <br />tY <br />W <br /> <br />W <br />C7 <br /> ----I--- DEPTH BOTTOM COAXIAL CABLE (FT) 24.0 <br /> ••-+ (TYPE OF BACKFILL AROUND STEEL CABLE Portland Cement <br /> /DEPTH TOP OF ANCHOR BOLT 26 <br />0 <br />~-~---'ELEV <br /> . <br />. <br /> ELEV./DEPTH BOTTOM OF STEEL CABLE (FT) 29.0 <br />NOTES: Inclinometer only, 50' of 3l8" steel cable, 30' of coax cable, 20' 3/4" PVC pipe for protective sheath ~ <br />PVC sealed with tape at bottom to prevent backflow of grout into PVC sheath ~ GEI Consultants, Inc. <br /> ENGLEWOOD COLORADO <br />