My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV05885
DRMS
>
Back File Migration
>
Revision
>
REV05885
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 1:04:33 AM
Creation date
11/21/2007 9:29:26 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
9/21/1999
Doc Name
WEST PIT INTERIM EVAPORATION POND SYSTEM CONSTRUCTION REPORT SAN LUIS PROJECT COSTILLA CNTY COLO
From
SHEPHERD MILLER
To
DMG
Type & Sequence
TR26
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.0 CONSTRUCTION QUALITY CONTROL <br />4.1 Earthwork <br />Earthwork was conducted according to the specifications. Debris and boulders were removed <br />during placement of fill, and moisture control was utilized where necessary to aohieve required <br />compaction. <br />A sheepsfoot compactor was used to compact fill that was placed in the evaporation area. Once <br />compaction was complete, rocks were removed, the surface was fine graded, and a vibratory <br />smooth-drum compactor was used to proof-roll the surface before placement of the liner. <br />Compaction of fill in the holding pond embankment was also done with a sheepsfoot compactor, <br />and moisture was added during placement of fill in order to obtain the required percent <br />compaction. Additional compaction was provided by equipment traffic. Lift thicknesses were <br />kept to less than 24 inches, and compaction testing was done according to specifications. Two <br />compaction tests were performed on the embankment fill, and both produced passing results. <br />Compaction test locations are shown on Figure 1, and the results aze presented in Appendix C. <br />Before concrete was poured for the pump and sprayer pads, rocks and other deleterious materials <br />were removed from the pad footprint and the surface was made level. The subgrade was then <br />proof-rolled using asmooth-drum compactor. <br />4.2 Liner <br />Liner installation was performed by National Seal Company of Reno, Nevada. The liner was <br />placed in accordance with construction and manufacturer specifications, and liner quality control <br />was conducted by National Seal. Destructive and non-destructive testing were performed at the <br />frequencies provided in the specifications. One failed test was documented, however passing <br />results were obtained during the retest. Quality control results and documentation were <br />periodically reviewed by the SMI Field Engineer during the course of liner installation, and <br />copies of the documentation are contained in Appendix A. <br /> <br />Battle Mounmin Resources, Inc. 5 August TO, /999 <br />