EXHIBIT G -WATER INFORMATION <br />The permd area ~ not prone to flooding from adjoining properties or the two nearby Spring Creek and Alkali <br />Creek, both of which are intermittent drainage channels. The predominate drainage course found kr the wGnity <br />of the site is the Eagle Rroer, which is north of the permit boundary and flows approwmately 60 feet below the <br />site A review of the Flood Rate Insurance Map for the area indcates, that none of the disturbed areas on the <br />site are prone fo flooding by the river <br />Mining ~s conducted in a manner that will not increase the discharged amount of surface stormwater runoff <br />above historic Vows, Any storm water runoff entering the site wdl be captured wdhin the pit area and allowed to <br />evaporate or percolate into the ground. In order to maintain the quality of any surface storm water, which <br />crosses any e~osed ground areas, a Stonn Water Management Plan (SWMP), has been prepared The <br />Colorado Department of Public Health and Environment has issued a permR, A key element of the plan calls <br />for grading the area in a manner that will not allow the discharge of any silt laden storm water from the property <br />in the event of a storm Thus, eliminating any stormwater discharges from the disturbed areas of the sRe This ~ <br />accomplished by utilizing a 3 foot high dike adjacent to and above the river The dike will duect flows to a <br />shallow Swale and ultimately to the existing pond area on the property, A drainage analysis is presented on the <br />following pages The analysis indicates that the various stormwater conveyance elementsare property s¢ed m <br />the event of a major storm event <br />Water is used on site when necessary to control dust in the mirnng area, duhng crushing operations, and on <br />haul roads Water for dust control La obtained from the aforementioned pond. Water is also consumed for the <br />operation of the wash plant The water supply for the consumptn2 uses is from extsUng water rights in the <br />Stremme and Gates Irrigation Ditch located on the property Water Ls pumped lrom an ewstng well adjacent to <br />the Eagle Rrver and stored in the existing pond Estimated mawmum annual water regwrements follow <br />• • <br /> AC. FT. <br />USE PER YEAR <br />Sand and Gravel Washin g 3.66 <br />Dust Control _ _ _ _ 6.54 <br />Concrete Production 1.84 <br />-- <br />Washing <br />Truck _ _0.45 <br />_ <br />Pond Evaporatron 3_98 <br />Domestic 0.06 <br />TOAL 16.55 <br />DEC 21200 <br />x ,~~~' ~r <br />5:1~ ~ .. , <br />~~ <br />Vu~w ~rl ffie' .~~is ling water storage and sediment pond. <br />