My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REV00108
DRMS
>
Back File Migration
>
Revision
>
REV00108
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2016 12:57:50 AM
Creation date
11/21/2007 8:43:10 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1988112
IBM Index Class Name
Revision
Doc Date
10/28/1999
Doc Name
ENVIRONMENTAL PROTECTION PLAN SAN LUIS PROJECT
Type & Sequence
TR27
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />21. Potentials to produce acid mine drainage. (see acid generationlneutralization <br />potential tests, humidity cell tests, baseline studies, Exhibits D.6.4.4 and D.3.3, <br />Appendix F, TR-018, and the TR-015 Response Plan) <br />6.4 Antiscalent (Hypersperse®) <br />22. The Potential Affects To Human Healih, Property And Environment Are Described <br />In The MSDS Sheets Located In Appendix A Of This Document. <br />23. Antiscalent Is Used To Chemically Modify The Influent Stream Just Upstream Of <br />The Nanofiltration Membranes To Prevent Scaling Of The Membrane Surfaces. <br />24. MSDS (See Appendix A Of This Document) <br />25. Disposal, Decommission, Detoxification, And Stabilization Of Antiscalent At The <br />Water Treatment Facility Is Discussed In Detail In The ERP. <br />26. The Antiscalent Used In The Water Treatment Process Is Stored In A Controlled <br />Area In The Water Treatment Building And Consideration Has Been Given In The <br />Engineering Design. (E.G., Secondary Containment) To Eliminate The Possibility Of <br />Antiscalent Release From The Facility (See The ERP). <br />27. Handling And Storage Of The Antiscalent Associated With The Operation Of The <br />Water Treatment Facility [s Described In The ERP. <br />• 28. Potentials To Produce Acid Mine Drainage. (See Acid GenerationMeutralization <br />Potential Tests, Humidity Cell Tests, Baseline Studies, Exhibits D.6.4.4 And D.3.3, <br />Appendix F, TR-018, And The TR-015 Response Plan) <br />7.0 FACILITIES EVALUATION <br />DEFIlVITION OF ENVIRONMENTAL PROTECTION FACILITY: A STRUCTURE WHICH <br />IS IDENTIFIED IN THE ENVIRONMENTAL PROTECTION PLAN AS DESIGNED, <br />CONSTRUCTED, AND OPERATED FOR CONTROL OR CONTAINMENT OF <br />DESIGNATED CHEMICALS, ACID MINE DRAINAGE, OR TOXIC OR ACID-FORMING <br />MATERIALS THAT WILL BE EXPOSED OR DISTURBED AS A RESULT OF MINING OR <br />RECLAMATION OPERATIONS. <br />The approved San Luis permit (Exhibits D.6 and E) and permit amendment as well as Technical <br />Revisions 10, 11, 13, l4, 19, 20, and 21 were submitted as appropriate facilities to provide for <br />environmental protection either during mining or following active mining. The location of the <br />• mill and tailings facility was specifically selected to provide for containment of mining related <br />Battle Mountain Resources, Inc. Shepherd Mdler Inc. <br />pd/00I6"b.arpp rm~lw: mrisrerppRl~d~ 7 Ocmber 28. 1999 <br />