Laserfiche WebLink
LTC- COMMEFCIAL TESTING b ENGINE EPING CO. <br />COLORADO - CDPS WET TEST REPORT FORM -CHRONIC <br />PERMTTTEE: Rag America Empire CDPS NO. CO-0034 ] 42 OUTFACE: 1 SP <br />TYPE TEST: ROUTINE: XX ACCELERATED:- TEST SPECIES: P.promelas <br />TEST RESULTS LETHALITY GROWTH STATISTICAL METHOD <br />Concentration with Statistical Difference 50.0% >100% Steel's Man -One Rank/Dunnett' <br />PasslFail Pass N!A <br />ICzs 30.7% 32.9% Bootstra <br />Pass/Fail Pass N1A <br />TEST TIME & DATE START 1105 AM 09/17/02 END 1020 AM 09124/02 <br />DILUTION (% EFFLUENT) <br />MEASUREMENTS CONTROL 11.5% 25% 50% 75% 100% <br />Da 1 % Survival 100 100 100 100 100 100 <br />Da 2 100 100 100 100 100 100 <br />Da 3 100 100 97.5 97.5 90.0 92.5 <br />Da 4 97.5 97.5 90.0 90.0 75.0 82.5 <br />Da 5 97.5 85.0 .87.5 75.0 70.0 65.0 <br />Da 6 97.5 75.0 85.0 55 0 70.0 62.5 <br />Da 7 97.5 72.5 85.0 50.0 52.5 60.0 <br /> <br />7 Da Mean Wei t 0.689 0.516 0.599 0.413 0.408 0.463 <br /> <br />H (Maximum/Minimum) 8.7/7.8 8.5/8.1 8.618.2 8.7/8.1 8.7!8.0 8.9/8.0 <br />RECEIVING WATER USED FOR DILUTION? NO TOTAL RESIDUAL C]- (mg/1): <O.l <br />HARDNESS (mg/1~ REC'V WATER: EFFLUENT 448 RECON WATER' 112 <br />ALKALINITY (mg/il: REC'V WATER: EFFLUENT: 567 RECON WATER 82 <br />TOT. AMMONIA ~m~l: INITIAL 100%: <1.0 FINAL 100%: <I.0 <br />WERE ALL TEST CONDITIONS IN CONFORMANCE WITH DIVISION GUIDELINES? NO <br />IF NO, LIST DEVIATIONS FROM TEST SPECIFICATIONS: Kit #3 was not delivered within the Droner <br />holding time due to a shipping error on the part of UPS A portion of kit #2 sample was used for day-5 <br />renewal. --~, <br />LABORATORY: COMMERCIAL TESTING & ENGINEERING ANALYST: l.~ ! _-- - <br />