My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO31567
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO31567
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:55:13 PM
Creation date
11/21/2007 2:01:33 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Hydrology
Doc Date
7/28/2006
Doc Name
Water Sample Results
From
CEMEX
To
DMG
Permit Index Doc Type
DMG Sampling
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Paragon Analytics <br />INORGANICS CASE NARRATIVE <br />CEMEX, Inc. <br />A and C Pit <br />Order Number - 0607003 <br />1. This report consists oft liquid samples. <br />2. The samples were received cool and intact on 07/01/06. The temperature of the <br />samples upon receipt was 8.0° Celsius. <br />3. The samples were prepared for analysis based on Methods for the Chemical <br />Analysis of Waters and Wastes (MCAWW), May 1994 procedures. <br />4. The samples were analyzed following MCAWW procedures for the following <br />methods: <br />Anal e Method SOP # <br />pH 150.1 112b Rev 15 <br />Specific conductance 120.1 1128 Rev 8 <br />5. All standards and solutions were used within their recommended shelf life. <br />6. The samples were prepared and analyzed within the established hold time for each <br />analysis. <br />All in house quality control procedures were followed, as described below. <br />7. General quality control procedures. <br />All initial and continuing calibration verifications (ICV(CCV) associated with <br />each analytical batch were within the acceptance criteria for the requested <br />analyzes. This indicates a valid calibration and stable instrument conditions. <br />8. Matrix specific quality control procedures. <br />Sample 0607003-3 was designated as the quality control sample for each analysis. <br />Similazity of matrix and therefore relevance of the QC results should not be <br />automatically inferred for any sample other than the native sample selected for <br />QC. <br />^ A sample duplicate was prepared and analyzed with each batch. All guidance <br />criteria for precision were met. <br />
The URL can be used to link to this page
Your browser does not support the video tag.