Laserfiche WebLink
LTA COMMERCIAL TESTING & ENGINEERINGGO. <br />sixce iwe. <br />COLORADO -CDPS WET TEST REPORT FORM - CFIRONIC <br />PERMITTEE: Bowie Resources Ltd. CDPS NO. CO-0044776 OUTFACE: Pond C <br />TYPE TEST: ROUTINE: XX ACCELERATED: TEST SPECIES: C. dubia <br />TEST RESULTS LETHALITY REPRODUCTION STATISTICAL METHOD <br />Concentration with Statistical Difference >100% >100% Fisher/Steel's Man -One <br />Pass/Fail Pass N/A <br />ICzs >100% >100% Bootstra <br />Pass/Fail Pass N/A <br />TEST TIME & DATE START 1110 AM 03/26/02 END 1010 AM 04/03/02 <br />DILUTION (% EFFLUENT) <br />MEASUREMENTS CONTROL 12.5% 25% 50% 75% 100% <br />Da 1 % Survival 100 100 100 100 100 100 <br />Da 2 100 100 100 100 100 100 <br />Da 3 100 100 100 100 100 100 <br />Da 4 100 100 100 100 100 100 <br />Da 5 100 100 100 100 100 100 <br />Da 6 100 100 100 100 100 100 <br />Da 7 100 100 100 100 100 100 <br /> <br />Mean 3 Brood Total 21.5 20.5 22.2 21.7 21.2 19.1 <br /> <br />pH (Maximum/Minimum) 8.8!8.3 9.0!8.3 9.0(8.4 9.0/8.4 8.9(8.4 8.9/8.4 <br />RECEIVING WATER USED FOR DILUTION? NO TOTAL RESIDUAL Cl- (mg/1): <0.1 <br />HARDNESS (mg/1): REC'V WATER: EFFLUENT: 392 RECON WATER 117 <br />ALKALINITY (mgJl): REC'V WATER: EFFLUENT: 297 RECON WATER: 85 <br />TOT. AMMONIA (mg/11: INITIAL 100%: <1.0 FINAL 100%: <I 0 <br />WERE ALL TEST CONDITIONS IN CONFORMANCE WITH DIVISION GUIDELINES? YES <br />IF NO, LIST DEVIATIONS FROM TEST SPECIFICATIONS: <br />LABORATORY: COMMERCIAL TESTING & ENGINEERING ANALYST: <br />^,-~ <br />~,.~ ~C.~ <br />4/14/99 <br />