My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO30758
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO30758
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:49:24 PM
Creation date
11/21/2007 12:47:48 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2001063
IBM Index Class Name
Hydrology
Doc Date
9/4/2002
Doc Name
Water Quality Results
From
DMG-HHP
To
DMG-RCO
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACIZ Laboratories, Inc. <br />9779 nnwnhill Onvn .Sieamhnat Snnnns CO RlMR7 /A001334- <br />Batch A distinct set of samples analyzed al a speck time <br />Found Value of the DC Type of interest <br />Limit Upper limit for RPD, in %. <br />Lower Lower Recovery Limit, in % (except for LCSS, mg/Kg) <br />MDL Method Detection Llmlt. Same as Minimum Reporting Limll. Allows for instrument and annual fluctuations. <br />PCN/SCN A number assgned to reagents/standards to trace to the manufacturer's certficate of analysis <br />PQL Practical Quantitation Limit, typically 5 times the MDL. <br />CC Tme Value of the Control Sample or the amount added to the Spike <br />Rec Amount of the We value or spike added recovered, in °~ (except for LCSS, mg/Kg) <br />RPD Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Upper Recovery Limit, in % (except for LCSS, mg/Kg) <br />Sample Value of me Sample of interest <br />AS Analytical Spike (Post Digestion) LFM Laboratory Fortified Matdx <br />ASO Analytical Spike (Post Digestion} Duptlcate LFMD Laboratory Fortified Matrix Duplicate <br />DUP Sample Duplicate LRB Laboratory Reagent Blank <br />LCSS Laboratory Control Sample -Soil MS/MSD Matriz SpikelMatdx Spike Duplicate <br />LCSW Laboretory ConVOI Sample -Water PBS Prep Blank -Soil <br />LFB Laboratory Forted Blank PBW Prep Blank -Water <br />Blanks Verifes that there is no or minimal contamination in the prep method procedure. <br />Control Samples Verifies the accuracy of the method, including the prep procedure. <br />Duplicates Verifies the precision of the insWment and/or method. <br />Spikes/Fortified Matrix Determines sample maVix intederences, 'rf any. <br />B Analyte concentration detected at a value between MDL and P!]L. <br />H Analysis exceeded method hold time. pH is a field test with an immediate hold time. <br />R Poor spike recovery accepted because the other spike in the set fell within the given limits. <br />T High Relative Percent Difference (RPD) accepted because sample concenVationsare less Nan 10x the MDL. <br />U Analyte was analyzed for but not detected at the indicated MDL <br />V High blank data accepted because sample concentration is 10 times higher than blank CAncenVation <br />W Poor recovery for Silver quality control is accepted because Silver often precipitates with Chloride. <br />X Quality control sample Is out of control. <br />Z Poor spike recovery is accepted because sample concenVafion is four times greater than spike concentration. <br />(1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes, Mamh 1983. <br />(2) EPA 600/R-93-100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993. <br />(3) EPA 600/R-94-111. Methods for the Determination of Metals in Environmental Samples -Supplement I, May 1994. <br />(5) EPA SW848. Test Methods for Evaluating Solid Waste, Third Edition with Update III, December 1996. <br />(6) Standard Methods (or the Examination of Water and Wastewater, 19th edition, 1995. <br />(1) OC results calculated from raw data. Results may vary slightly if the rounded values are used in the calculations. <br />(2) Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br />(3) Animal matdces for Inorganic analyses are reported on an "as received" basis. <br />REPIN03.11.00.01 <br />L37592: Page 6 of 9 <br />