My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO30060
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO30060
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:48:52 PM
Creation date
11/20/2007 11:52:18 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Hydrology
Doc Date
2/8/2006
Doc Name
Water Sample Results and Level
From
CEMEX Inc.
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
different than those in the ICV, and a readback of the highest calibration <br />standard. <br />These solutions provide verification that the cahbration equations are <br />functioning properly throughout the analytical range of the instrument. During <br />sample analysis dilutions are made for analytes found at concentrations above <br />the highest calibration standard. No results are taken from extrapolations <br />beyond the highest standard. <br />6. All standazds and solutions aze NIST traceable and were used within their <br />recommended shelf life. <br />7. The samples were prepazed and analyzed within the established hold times. <br />All in house quality control procedures were followed, as described below. <br />8. General quality control procedures. <br />^ A filter (method) blank and laboratory control sample were filtered, preserved <br />and prepazed at the same time as the samples for the selenium analysis. A filter <br />(method) blank was filtered, preserved and prepared at the same time as the <br />samples for the thallium analysis. There were not more than 20 samples <br />associated with each filtered blank and laboratory control sample. <br />^ The preparation (method) blank associated with each batch was below the <br />practical quantitation limit for each requested analyte. <br />^ -The ]aboratory control sample associated with the selenium batch was within <br />the acceptance limits. <br />^ All initial and continuing calibration blanks associated with this analytical batch <br />were below the practical quantitation limits for the requested analytes. <br />^ All initial and continuing calibration verifications associated with this analytical <br />batch were within the acceptance criteria for the requested analytes. This <br />indicates a valid calibration and stable instrument conditions. <br />^ The interference check samples associated with Method 200.8 were analyzed. <br />9. Matrix specific quality control procedures. <br />Sample 0512199-I was designated as the quality control sample for each analysis. <br />Similarity of matrix and therefore relevance of the QC results should not be <br />automatically inferred for any sample other than the native sample se]ected for QC. <br />^ A matrix spike and matrix spike duplicate were prepared and analyzed with <br />each batch. All acceptance criteria for accuracy were met with the following <br />exceptions: <br />Anal e Sample ID <br />Thallium 0512199-1MS & MSD <br />The native sample result is flagged for matrix spike failure. <br />
The URL can be used to link to this page
Your browser does not support the video tag.