Laserfiche WebLink
CASE NARRATIVE <br />D3H080357 <br />The following report contains the analytical results for three water samples submitted to STL Denver by <br />Blasland, Bouck & Lee from the liolcim Site. The samples were received August 8, 2003, according to <br />documented sample acceptance procedures. - <br />Dilution factors and footnotes have been provided on each data sheet to assist in the interpretation of the <br />results. In some cases, due to interferences or analytes present above the linear calibration curve, <br />samples must be analyzed at a dilution. For samples analyzed at a dilution, the reporting limits are <br />adjusted relative to the dilution required. Dilutions made for reasons other than the presence of target <br />compound(s) are addressed in the Supplemental Information Section. <br />STL Denver utilizes USEPA approved methods in all analytical work. The samples presented in this <br />report were analyzed for the parameters listed on the methods summary page in accordance with the <br />methods indicated. QC data for these analyses are included. <br />The results included in this report have been reviewed for compliance with the laboratory QA/QC plan. All <br />data have been found to be compliant-with the exception of those items noted. The test results shown in <br />this report meet all requirements of NELAC. Any exceptions are noted in the Supplemental Information <br />Section below. <br />Supplemental QC Information <br />Sample Arrival and Receipt <br />The samples presented in this report were received at the laboratory in good condition and at <br />temperatures of 4.5°C. <br />Per client instruction, samples should be logged per the quote. <br />No anomalies were observed. <br />Total Metalsl200.8/200.7!245.1 <br />Thallium and Barium are present in the. method blank- associated with QG batch 3221134. Because the <br />concentrations in the method blanks are riot present at levels greater-than the reporting limits, corrective <br />action is deemed unnecessary. <br />Aluminum is present in the method blank associated with QC batch 3221191. Because the concentration <br />in the method blank is not present at a level greater than the reporting limits, corrective action is deemed <br />unnecessary. <br />The laboratory generated MS/MSD associated with QC batch 3221191 exhibited percent recoveries <br />outside the QC control limits for Aluminum and Sodium. The acceptable LCS analysis data indicated that <br />the analytical system was operating within control; therefore, corrective action is deemed unnecessary. <br />Percent recoveries and RPD data could not be reliably calculated for the laboratory generated Calcium <br />MS/MSD associated with QC batch 3221191, due to the sample concentrations reading greater than four <br />times the spike amounts. <br />No other anomalies were observed <br />