Laserfiche WebLink
CASE NARRATIVE <br />D4G090452 <br />The following report contains the analytical results for one water sample submitted to STL Denver by <br />Blasland, Bouck & Lee from the Holcim Portland Site. The samples were received July 9, 2004, according <br />to documented sample acceptance procedures. <br />Dilution factors and footnotes have been provided on each data sheet to assist in the interpretation of the <br />results. In some cases, due to interference or analytes present above the linear calibration curve, samples <br />must be analyzed at a dilution. For samples analyzed at a dilution, the reporting limits are adjusted <br />relative to the dilution required. Dilutions made for reasons other than the presence of target <br />compound(s) are addressed in the Supplemental Information Section. <br />STL Denver utilizes USEPA approved methods in all analytical work. The sample presented in this report <br />was analyzed for the parameters listed on the methods summary page in accordance with the methods <br />indicated. QC data for these analyses are included. <br />The results included in this report have been reviewed for compliance with the laboratory QA/OC plan. All <br />data have been found to be compliant with the exception of those items noted. The test results shown in <br />this report meet all requirements of NELAC. Any exceptions are noted in the Supplemental Information <br />Section below. <br />Supplemental QC Information <br />Sample Arrival and Receiat <br />The sample presented in this report was received at the laboratory at a temperature of 4.6°C. <br />No anomalies were observed. <br />Total Metals/200.8l200.7/245.1 <br />Aluminum, Calcium, Sodium and Zinc were detected in the method blank associated with QC batches <br />4795374 and 4197233. Because the level in the method blank is not present at a level greater than the <br />reporting limit, corrective action was deemed unnecessary. <br />The MS and/or A4SD associated with QC batch 4195374 was performed using sample MW-10. The <br />MS/MSD exhibited percent recoveries outside the QC control limits for Aluminum and Potassium. The <br />acceptable LCS analysis data indicated that the analytical system was operating within control; therefore, <br />corrective action was deemed unnecessary. <br />The Calcium, Magnesium and Sodium recoveries and Relative Percent Difference (RPD) for the MS/MSD <br />associated with QC batch 4195374 could not be calculated because the sample amount was greater than <br />four times the spike amount. The acceptable LCS analysis data indicated that the analytical system was <br />operating within control; therefore, corrective action was deemed unnecessary. <br />All other QC data was in control. <br />No other anomalies were observed. <br />General Chemistry <br />Each sample is analyzed to achieve the lowest possible reporting limits within the constraints of the <br />methods. Due to high constituent concentration, the Nitrate-Nitrite, Nitrite and Sulfate analyses for sample <br />