Laserfiche WebLink
Underground Injection Control Branch Guidance No.: <br />., , <br />w~yg://35/ht t p:l/www. epa.gov/reg5oh 20/u i dr5_O5. h t m <br />1. Annulus pressure increases and tracks injection pressure -probable tubing or packer leak; <br />2. Annulus pressure decreases: <br />a. and goes to near zero -probable casing leak; <br />b. stabilizes and returns to normal behavior -possible packer slip; <br />3. Annulus pressure is very stable regardless of injection -probable deep casing leak in well ~ <br />light annulus liquid; <br />4. Annulus pressure fluctuates -probable temperature effects due to operational effects of <br />injectate temperature changes; <br />For wells with injection pressure greater than zero but less than annulus pressure <br />Annulus pressure increases - if [he well is deep, penetrates high pressure zones, and the <br />annulus liquid is light it may indicate a deep casing leak, possibly due to an increase in <br />injectate temperature; <br />Annulus pressure decreases: <br />a. to near zero and/or becomes very stable -probable deep casing leak in well with ligh <br />annulus liquid: <br />b. and tracks injection pressure -probable tubing leak; <br />c. stabilizes, and resumes normal behavior - could be a decrease in average injectate <br />temperature or packer slip; <br />3. Annulus pressure fluctuates -probable temperature effects due to operational effects of <br />injectate temperature changes; <br />For wells which inject on a vacuum <br />Annulus pressure decreases -could be either a casing, tubing, or packer leak; <br />2. Annulus pressure increases: <br />a. and stabilizes - if [he well is deep, penetrates high pressure zones, and the annulus lit <br />is light it may indicate a deep casing leak; <br />b. and begins to behave normally at a higher pressure -possibly due to an increase in <br />injectate temperature. <br />In the event that a loss of MI is suspected an SAPT should be performed to ensure that the well <br />MI. If the SAPT conFirms MI, then the operator may resume [he use of the SAMT. <br />ATTACHMENT 3 <br />RADIOACTIVE TRACER SURVEY (RTS) <br />FOR DEMONSTRATION OF 146.8(a)(1) <br />A. Basis <br />During injection, radioactive (RA) tracers can be added [o injected liquids at a point above the <br />12 0(34 ~ 5!28/99 1:09 PM <br />