Laserfiche WebLink
PERIODIC INSPECTION FORM <br /> Water, Sediment, or Slurry Impoundments <br /> <br />' ` <br />I Q 'L~' ~ <br />INSPECTOR S NAME: Dennis Jones DATE: <br />U <br />NPDES I.D. NO.: CO-0000221 D.P. 015 ( <br />0 / <br />FACILITY CONFIGURATION: Cross-Valley Pond ~ <br />DATE LAST INSPECTION: ~ ` <br />l C~ <br />SITE NAME: Pond #015 LOCATION: NE'/, SE'/, Sec. 23, TSN R88W <br />MINE NAME: Seneca II-W Mine (Seneca Coal Co ) LOCATION: 8 mi. S of Ha yden. CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S REP.: Gregg Kitchen Gen Mar <br />Circle or write in appropriate response <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />Foundation preparation (removal of vegetation, stumps, topsoil <br />Lift thickness: <br />Yes <br />12 <br />Compaction according to approved plan: <br />Burning (specify extent and location): <br />Angle of slope: 2.5:1 upstream, 3.5:1 downstream <br />*Seepage (specify location, color, and approximate volume) <br />_ Yes <br />_ No <br />Total = 6:1 <br />From underdrain pipes: <br />At isolated points on embankment slopes: Yes No <br />At natural hillside: Yes No <br />Over widespread areas: Yes No <br />From downstream foundation area: Yes No <br />"Boils" beneath stream or ponded water: Yes No <br />Cracks or scarps on crest: Yes No <br />Cracks or scarps on slope: Yes No <br />Sloughing or bulging on slope: Yes No <br />*Maj or erosion problems: Yes No <br />Surface movements in valley bottom or o n hillside: Yes No <br />*Erosion of toe: Yes No <br />*Water impounded against toe: Yes No <br />Existing embankment freeboard: (normal = 4.0') ~.0 feet <br /> <br />Increase Decrease in water level: O •~ feet <br />Cracks, bulging, or erosion on upstream face: Yes <br />Visible sumps or sinkholes in slurry surface: <br />*Clogging <br />Spillway channels and pipes: <br />Decant system: <br />Diversion ditches: <br />*Cracking or crushing o£ pipes <br />Spillway pipes: <br />Decant system: <br />Trash racks clear and in place: <br />Yes No <br />NL <br />Yes <br />Yes No <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />*Major adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />