HYDRO29165
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO29165
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:48:12 PM
Creation date
11/20/2007 10:26:06 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2002004
IBM Index Class Name
Hydrology
Doc Date
11/13/2003
Doc Name
Transmittal of Groundwater Analytical Results
From
GCC Rio Grande Inc.
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Brown and Caldwell ACZ Project ID: L42294 <br />.- .. <br /> <br />L42294-01 WG160043 Calcium, dissolved M200.7 ICP MA One spike recovery was outside of the method limits: the <br /> tluplicate spike and the method control recoveries were <br /> within the method limits. <br />WG160012 Iron, tlissolved M200.7 ICP BC Target analyte detected in calibration blank at or above <br /> method reporting limit. Concentration found in the sample <br /> was 20 times above the concentration found in the <br /> calibration blank. <br /> Manganese, dissolved M200.7 ICP M2 Matrix spike recovery was low, the method control sample <br /> recovery was acceptable. <br /> M200.7 ICP ZK Target analyte tletecled in the blank as a negative result al <br /> or above the negative method limit (i. e. high negative bias). <br /> Sample wncenlration is al a minimum ten times greater <br />. than positive method reporting limit. <br />WG161715 Mercury, dissolved M1631, Atomic Fluorescence H7 Sample analysis pertortned past holding time. See case <br /> narrative. <br />L42294-02 WG160043 Calcium, dissolved M200.7 ICP MA One spike recovery was outside of the method limits; the <br /> duplicate spike antl the melhotl control recoveries were <br /> within the method Ilmlta. <br />WG160012 Iron, dissolved M200.7 ICP BC Target analyte detected in calibration blank at or above <br /> method reporting limit. Concentration found in the sample <br /> was 20 times above the concentration found in the <br /> calibration blank. <br />Manganese, dissolved M200 7 ICP M2 Matrix spike recovery was low, the method control sample <br /> recovery was acceptable. <br /> M200 7 ICP ZK Target analy[e detected in the blank as a negative result at <br /> or above the negative method limit (i.e. high negative bias). <br /> Sample concentration is at a minimum ten times greater <br /> than positive method reporting limit. <br />WGi61715 Mercury, dissolved M1631, Atomic Fluorescence Hi Sample analysis performed Oast holding time. See case <br /> narrative. <br />L42294-03 WG160043 Calcium, dissolved M200.7 ICP MA One spike recovery was outside of the method limits; the <br /> duplicate spike and the melhotl control recoveries were <br /> within the melhotl limits. <br />WG160012 Manganese, dissolved M200.7 ICP M2 Matrix spike recovery was low, the method control sample <br /> rewvery was acceptable. <br /> M200.7 ICP ZK Target analyte detected in the blank as a negative result at <br /> or above the negative melhotl limit (i.e. high negative bias). <br /> Sample wncentration is at a minimum ten times greater <br /> than positive method reporting limit. <br />WGi61715 Mercury, dissolved M1631, Atomic Fluorescence Hi Sample analysis performed past holding time. See case <br /> narrative. <br />L42294-04 WG160043 Calcium, dissolved M200.7 ICP MA One spike rewvery was outside of the method limits; the <br /> duplicat¢ spike and the method control recoveries were <br /> within the method limits. <br />WG160012 Iron, dissolved M200.7 ICP BC Target analyte detected in calibration blank at or above <br /> method reporting limit Concentration fountl in [he sample <br />- was 20 times above the wncentration fountl in the <br /> calibration blank. <br />Manganese, dissolved M200.7 ICP M2 Matrix spike rewvery was low, the method control sample <br /> recovery was acceptable. <br /> M200.7 ICP ZK Target analyte detected in the blank as a negative result at <br /> or above the negative method limit (i.e. high negative bias). <br /> Sample concentration is at a minimum ten times greater <br /> Than positive method reporting limit. <br />WG161716 Mercury, dissolved Mi631, Atomic Fluorescence H1 Sample analysis pertormetl past holding lime. See case <br /> narrative. <br />L42294-05 WG160043 Calcium, dissolved M200.7 ICP MA One spike rewvery was outside of the method limits; the <br /> duplicate spike and the method control recoveries were <br /> within the method limits. <br />L42294-g6 WG161715 Mercury, tlissolved M1631, Atbmic Fluorescence H1 Sample analysis pertormetl past holtling lime. See case <br /> narrative. <br />EXTQUAL.11.20.02.01 <br />L42294: Page 17 of 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.