My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO29139
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO29139
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:48:10 PM
Creation date
11/20/2007 10:24:36 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977215
IBM Index Class Name
Hydrology
Doc Date
1/13/1995
Doc Name
BULLDOG MINE GROUNDWATER
From
HOMESTAKE
To
WQCD
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Enseco <br />A G•minF Cnm~an• <br />~~ <br />~~- <br />~' <br />i~ <br />1' <br />1~ <br />1~- <br />1' <br />~~- <br />1~ <br />~. <br />~' <br />Introduction <br />This report presents the analytical results as well as supporting <br />information to aid in the evaluation and interpretation of the data and is <br />arranged in the following order: <br />o Sample Description Information <br />o Analytical Test Requests <br />o Analytical Results <br />o Quality Control Report <br />All analyses at Enseco are performed so that the maximum concentration of <br />sample consistent with the method is analyzed. Dilutions are at times <br />required to avoid saturation of the detector, to achieve linearity for a <br />specific target compound, or to reduce matrix interferences. In this event, <br />reporting limits are adjusted proportionately. Surrogate compounds may not be <br />measurable in samples which have been diluted. <br />Enseco-RMAL's furnace analysis decision tree is based on a single-point <br />method of standard addition as described in Method 7000. We recoveries exceed <br />normal limits, the reporting limit is raised or the sample is diluted and <br />reanalyzed. The reporting limits for the total arsenic analysis of samples <br />032916-0002, -0004 and -0005 were raised due to matrix interferences. The <br />reporting limit for the dissolved lead analysis was raised due to matrix <br />interferences. Samples -0001 through -0005 required dilutions for the total <br />cadmium analysis due to the concentrations of cadmium present in the samples <br />beyond the linear range `of the instrument. The reporting limits are adjusted <br />accordingly. Sample -0001 also required a dilution for the dissolved cadmium <br />analysis. Some of the dissolved zinc results are greater than the total zinc <br />results. Since the values are similar, the data was accepted and reported. <br />The TDS/Conductance ratio used as an internal check was not met for <br />samples -0003, -0004 and -0005. These samples were reanalyzed. The results <br />were confirmed for samples -0004 and -0005. The TDS/Conductance ratio from <br />the reanalysis of sample -0003 was improved; therefore, the reanalysis data <br />was reported. This reanalysis occurred outside of holding times. <br />
The URL can be used to link to this page
Your browser does not support the video tag.