Laserfiche WebLink
~9E~ <br />CORE LABORATORIES <br />g U A L I T Y A S S U R A N C E M E T H O D S <br />REFERENCE S A N D N O T E S <br />Report Oat e: 12/29/98 <br />EXPLANATION OF DATA OUALI FIERS - ORGANIC PARAMETERS <br />U - This qualifier indica [es [ha[ [he analyte was analyzed <br />for but not detected. <br />J - Organic GC/MS Methods: This qualifier indicates that <br />the value is an estimate. It is used when a compound <br />is determined to be present based on the mass spectral <br />data but at a concentration below the practical <br />quantitation limit of the method. <br />J - Organic GL Methods: This qualifier indicates <br />presumptive evidence of the presence of the <br />compound at an estimated quantity. <br />E - This qualifier indicates that a sample result is an <br />estimate because the concentration exceeded the upper <br />calibration range of the instrument. <br />EXPLANATION OF DATA OUALI FIERS - METALS 6 INORGANIC PARAMETERS <br />U - This qualifier indicates that the analyte was analyzed <br />for but not detected. <br />B - This qualifier indicates that the analyte was detected <br />at a level bel ou the reporting limit but greater than <br />or equal to the instrument detection limit. <br />EXPLANATION OF DATA FLAGS - ALL PARAMETERS <br />B - This flag indicates that an analyte is present in <br />the method blank as cell as in [he sample. The client <br />should consider this when evaluating the data. <br />E - This flag indicates the reported value is estimated due <br />to sample matrix interference. <br />W - This flag indicates that a post-digestion spike for <br />GFAA analysis is outside quality control limits. <br />X - This flag indicates that a surrogate recovery is <br />outside quality control limits. <br />Y - This flag indicates a spike or spike duplicate recovery <br />is outside quality control limits. <br />2 - This flag indicates a relative percent difference for <br />a spike and spike duplicate is outside quality <br />control limits. <br />* - This flag indicates a relative percent difference for <br />a duplicate analysis is outside quality control <br />limits- <br />- This flag indicates a percent recovery fora standard <br />is outside quality control limits. <br />Page 3 <br />~...„u ,_,. ,.~ ~.,, ~..~, r <br />..o......, ,.~,...., ~~. ~....wm.,..~ c... um„~o.,.. «., ~u.,.,,~..,., ~.,...~. m,~...o ..~~„~ ,...o,,.a~,~,~~ ..o,.. ,. ,.,o,.u .., ,.,. ~,,..ro ~.~~..,~.,,,~~„m, ;~r.., ,e ~~„ o,o~,,:,,,,,. Poop, or«., a.. ~ o.,~„~~.,,..: o~ <br />,., a r, .»~,. „M, m,ro.n~ ~,.o.~, ..~ ~, ..w,~ «„~F,...,,~.s .,,.,.a„...,..,.. ,.~., .oe~ ~.,, ... ,,.e..~,~....... ~~„ ~.~„ ,~.~~ m~ ~...~, a.~~ . «.~~. e, ~. ~.~ ..~~.~ ~~.,,~~~.~.,,~,,,.~„c.~.,.m..~...., <br />