Laserfiche WebLink
<br />EPA- or ASTM-accepted method. <br />"Sampling Frequencies:" <br />The "normal frequency of sampling" for the underdrain system shall be weekly (one sample per <br />week) for analysis for the water-quality parameters identified in this commitment until such time <br />as CC&V makes an alternative proposal that is acceptable to the OMLR. This frequency may <br />be required to be temporarily increased, under certain conditions described below. <br />The "normal frequency of sampling" for the Leak Detection System ("LDS") shall be weekly <br />(one sample per week) providing water is present in adequate amount for pumping, for analysis <br />of the water-quality parameters identified in this commitment until such time as CC&V makes <br />an alternative proposal that is acceptable to the OMLR. This frequency may be required to be <br />temporarily increased at certain locations, under certain conditions described below. <br />The "normal frequency of sampling" for designated ground-water wells shall be monthly weekly <br />(one sample per 30 or 31 days) providing water is present in adequate amount for pumping, for <br />analysis of the water-quality parameters identified in this commitment until such time as CC&V <br />makes an alternative proposal that is acceptable to the OMLR. This frequency may be required <br />to be temporarily increased at certain locations, under certain conditions described below. <br />"Not exceeded" as used in the protocols is defined as follows: the exceedences defined above <br />in Tables 1-3 will not exist if three consecutive surface water samples taken at AG-01.5 on three <br />consecutive days have WAD cyanide and pH equal to or less than the criterion defined in Table <br />1; or if five consecutive LDS samples taken five days apart have WAD cyanide less than or <br />equal to the numeric concentrations identified n Table 2; or if ground water concentrations <br />decrease so as to not exceed the concentration criterion listed in Table 3 for two consecutive <br />samples collected at least one week apart. <br />Protocols: <br />Underdrain System: If the CNW„p concentration and pH in the underdrain system exceeds the <br />values listed in Table 1, CC&V shall undertake the following steps: <br />a. Notify the OMLR by telephone within 3 working days of having knowledge of the <br />combination of elevated water-quality parameters. <br />b. The frequency of monitoring shall be increased to 4 samples per 7 days until the <br />concentrations listed in Table 1 are not exceeded or until it is shown to the satisfaction of the <br />OMLR that the increased frequency is not required because pertinent information is not being <br />generated. <br />c. If both of these concentrations listed in Table 1 are exceeded for more than 90 days, or if <br />the levels rise to <_2.0 mg/1 CNWAp and <_9.5 s.u., CC&V will consider there to be a defect <br />in the active Cresson Valley Leach Facility that allows CN-bearing solution from that facility <br />to move into the surrounding environment and will combine this information with the <br />2 <br />