Laserfiche WebLink
PERIODIC INSPECTION FORM <br />Water, Sediment, or Slurry Impoundments <br />Ron Gehrke 08/01/91 <br />INSPECTOR'S NAME: DATE: <br />NPDES I D NO - D P 004 <br />FACILITY CONFIGU Cross-Valley Pond DATE LAST INSPECTION: 05/07/91 <br />SIT E NAME: South Section 12 Pond #004 LOCATION:SW'I,SE'l~, Sec.1 <br />MIN E NAME: eneca ine ea o y oa o LOCATION: mi. o ay en, <br />MIN E I.D. N .: ermit - - OWNER'S R .:Scott Williams, Su pt <br /> Circle or write in appropriate response <br />1. Foundation preparation (removal of vegetation, stumps, topsoil): ~ No N/A <br />2. Lift thickness: 12 in. N/A <br />3. Compaction according to approved plan: es No N/A <br />4. Burning (specify extent and location): Yes No N/A <br />5. Angle of slope: 5:1 upstream, 2:1 downstream Total = 7:1 N/A <br />6. *Seepage (specify location, color, and approximate volume) <br /> From underdrain pipes: Yes Po N/A <br /> At isolated points on em an ment s opes: Yes N N A <br /> At natural hillside: Yes N/A <br /> Over widespread areas: Yes N/A <br /> From downstream foundation area: Yes N/A <br /> "Boils" beneath stream or ponded wa er: Yes N/A <br />7. Cracks or scarps on crest: Yes N~ N/A <br />8. Cracks or scarps on slope: Yes Jo N/A <br />9. Sloughing or bulging on slope: Yes NCg~ N/A <br />10. *Major erosion problems: Yes ® N/A <br />11. Surface movements in valley bottom or on hillside: Yes ~ N/A <br />12. *Erosion of toe: Yes No N/A <br />13. *4later impounded against toe: Yes N N/A <br />14. Existing embankment freeboard: 4'7 feet <br />15. Increase Decrease in water level: -~ feet <br />16, Cracks, bulging, or erosion on upstream face: Yes No N/A <br />17. Visible sumps or sinkholes in slurry surface: Yes No . (1~) <br />18. *Clogging <br /> Spillway channels and pipes: Yes No N/A <br /> Decant system: Yes N/A <br /> Diversion ditches: Yes o N/A <br />19. *Cracking or crushing of pipes <br /> Spillway pipes: Yes No N/A <br /> Decant system: Yes o N/A <br />20. Trash racks clear and in place: Yes / No N/A <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse condi- <br />tions noted in these items should normally be described (extent, location, volume, etc.) <br />in the space on the back of this sheet. <br />