Laserfiche WebLink
PERIODIC INSPECTION FORM <br /> -water, Sediment, or Slurry Impoundments <br />INSPECTOR 'S NAME: Dennis Jones DATE: 06/19/01 <br />NPDES I.D . NO.: CO-0000221 D.P. 006 <br />FACILITY CONFIGURATION: Cross-Valley Pond DATE LAST INSPECTION: 03/29/01 <br />SITE NAME : Pond #006/Pre-Settling Basin LOCATION: NW'/a NW'/a, Sec. 22. TSN. R88W <br />MINE NAME : Seneca II-W Mine (Seneca Coal Co l LOCATION: 8 mi. S of Hayden. CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S REP.: Greg g Kitchen Gen Mar <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />6 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />Circle or write in ayyrooriate reeoonae <br />Foundation preparation (removal of vegetation, stumps, topsoil: Yes No NfA <br />Lift thickness: 12 in. N/A <br />Compaction according to approved plan: Yes No N/A <br />Burning (specify extent and location): Yes No N/A <br />Angle of slope: 3:1 upstream, 3:1 downstream Total = 6:1 N/A <br />*Seepage (specify location, color, and approximate volume) <br />From underdrain pipes: Yes No NL <br />At isolated points on embankment slopes: Yes N N/A <br />At natural hillside: Yes No N/A <br />Over widespread areas: Yes No N1A <br />From downstream foundation area: Yes No N/A <br />"Boils" beneath stream or ponded water: Yes No N/A <br />Cracks or scarps on crest: Yes No N/A <br />Cracks or scarps on slope: Yes No N/A <br />Sloughing or bulging on slope: Yes No N/A <br />*Maj or erosion problems: Yes No N/A <br />Surface movements in valley bottom or on hillside: Yes No N/A <br />'Erosion of toe: Yes No N/A <br />*Wa ter impounded against toe: Yes No N/A <br />Existing embankment freeboard: (normal = 8 5') 9.5 feet <br />Increase x Decrease in water level: 1.0 feet <br />Cracks, bulging, or erosion on upstream face: Yes No N/A <br />Visible sumps or sinkholes in slurry surface: Yes No N A <br />*Clogging <br />Spillway channels and pipes: <br />Decant system: <br />Diversion ditches: <br />*Cracking or crushing of pipes <br />Spillway pipes: <br />Decant system: <br />Trash racks clear and in place: <br />Yes No N/A <br />Yes o NL <br />Yes No N/A <br />Yes Flo N/A <br />Yes No NL <br />Yes No N/A <br />*Maj or adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />