My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO28521
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO28521
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:47:43 PM
Creation date
11/20/2007 9:33:01 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1992081
IBM Index Class Name
Hydrology
Doc Date
11/19/1998
Doc Name
HAYDEN GULCH TERMINAL INC PN C-92-081 QUARTERLY POND INSPECTION REPORTS
From
MONTGOMERY WATSON
To
DMG
Permit Index Doc Type
SEDIMENT POND INSPECTIONS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HAYDEN GULCH TERMINAL, INC. <br />Hayden Gulch Loadout Facility <br />Permit No. C-92-OSI <br />Quarterly Sedimentation Pond InspeMion Report <br />Date of Inspection: August 21, 1998 Date last Inspected: May 22, 1998 <br />Pond: Rail Loop Pond (002A) Pond Location: SEl/4SE1/4Sec.14T6NR88W <br />NPDES ID No.: COG850006-002A $i[e Location: 2 mi. SE of Hayden, CO <br />Facility Configuration: Embankment Pond Owner's Rep: Tom Petrosky, Agent <br />Wa[er Level (above or below principal spillway): Above Below X <br />3 Ft.. <br />Sediment Level (below dewatering orifice [designated sedvnent level: _ <br />> 4 Ft.. <br />Sediment Removal Required: Yes No <br />Outflow: o cfs <br />FEATURE PROBLEM COMMENTS <br /> YES NO <br />EROSION <br />Rills & Gullies on Embankment X <br />Wave Erosion X <br />Spillway Erosion X <br />Burrows X <br />Other X <br />STRUCTURAL <br />Differential Settling X <br />Cracks or Slides X <br />Seepage X <br />Other X Embankment needs seedin <br />STRUCTURES <br />Principal Spillway X <br />Clogged Orifice X <br />Clogged or Damaged Culvert X <br />Damaged Headgate X <br />Emergency Spillway X <br />Erosion X <br />Riprap X <br />Clogged or Damaged Culver X <br />Other X <br />Maintenance Required: New embankment needs [o be seeded. Seeding will occur in fall when moisture conditions <br />are conducive to seed germination. <br />Maintenance Performed: None <br />Additional Commen[s: Sediment fence installed along toe of embankment looks ok. Water level 3 - 4 feet below <br />invert of combination spillway. No signs of erosion. No inflow. No discharge during <br />uartef. <br />NAME OF INSPECTOR: john C. Weinman <br />c, ::_ ; <br />i. S ~ ~. <br />~;>~~~ i~ N Ai 1~~C~ ~\\\ <br />
The URL can be used to link to this page
Your browser does not support the video tag.