Laserfiche WebLink
<br />t Appendix A <br /> Western Mobile <br /> Constant Discharge Pumping Test <br />' Shupe Wcll Test -Permit Numb er 123108-A <br /> Time (min) Water Les~el (ft) Drawdown (ft) <br />' 0 4.80 0.00 <br /> 1 7.70 2.90 <br /> 2 7.80 3.00 <br />' 3 7.80 3.00 <br /> 4 7.90 3.10 <br /> 5 8.00 3.20 <br /> 6 8.00 3.20 <br /> 7 8.00 3.20 <br /> 8 8.00 3.20 <br /> 9 8.05 3.25 <br />' l0 8.10 3.30 <br /> 17 8.20 3.40 <br /> 20 8.40 3.60 <br /> 25 8.60 3.80 <br />' 30 8.50 3.70 <br /> 35 8.60 3.80 <br />' 40 8.65 <br />45 8.70 3.85 <br />3.90 <br /> 50 8.70 3.90 <br /> 55 8.75 3.95 <br />' 60 8.75 3.95 <br /> 65 8.75 3.95 <br /> 70 8.75 3.95 <br /> 75 8.75 3.95 <br /> 80 8.75 3.95 <br /> 85 8.80 4.00 <br /> 100 3.90 -1.10 <br />' 105 8.90 4.I0 <br /> 110 8.95 4.15 <br /> 115 8.90 4.10 <br />t I20 8.90 4.10 <br /> Notes: <br /> Test conducted Mar. 20, 1999 <br />t Q measured with totalizing tlow meter. <br /> A~~g. Q = 21.98 gpm. <br /> Well radius = 0.58 feet. <br /> <br /> <br />1 <br />1 <br />' mrn k'akm Ma We Dau bu rvb), 1]i09 <br />