Section_Exhibit Name
EXHIBIT 16 MSHA ROOF AND VENTILATION PLANS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TEMPORARY SUPPORT <br />~ AND BOLT/NG' SEQUENCE <br />Sel before <br />bo/tiny begins <br />~, ~;,:: <br />, , <br />Corp I J Corp <br />j :: ~ D <br /> <br /> ~~ <br /> <br />~~ ` <br />O :; <br />4or8 4aB <br />• • <br />row of permanent support. <br />LEGEND <br />• Roof Bo/1 <br />D Safely /oeA' or T/tuber <br />® Installation Sequence Fa Safety Jade or Timber <br />Scaly I"= 10' <br />NOTE <br />Temporary supports wi// be insto/%d on/y if <br />roof bo/frog machines ore not equipped wish an operob/e <br />oparoved Automated Temporary Root Supports (ATRSJ. <br /> <br />lnsto// first row of bo/Js, <br />Then advance safety props os shown. <br />Figure K-3 <br />->.a- <br />