Laserfiche WebLink
PERIODIC INSPECTION FORM <br />stockponds or Sumps <br />INSPECTOR'S NAME: M' ha ~ Al av' ~a DATE: 09/22/99 <br />FACILITY CONFIGURATION: ~ o. ~nA DATE LAST INSPECTION: OG~/29/99 <br />SITE NAME: T-2 LOCATION: sElrcWlt cec 2 TSN n87W <br />MINE NAME: Seneca iI LOCATION: 7.1 mi cE of Haydn CO <br />MINE I.D. NO.: C-80-005 OWNER'S REP.: Arad Brown. Gen Mar <br />1. Angle of elope: gel upstream, 2.75:1 downstream Total = 4.7S:t N/A <br />2. *Seepage (specify location, color, and approximate volume) <br /> At isolated points on embankment elopes: Yes /[vo/ N/A <br /> At natural hillside: Yee N N/A <br /> <br /> Over widespread areas: Yes ~ N/A <br /> From downstream foundation area: Yee ~ N/A <br /> "Boils" beneath stream or ponded water: Yee No N/A <br />3. cracks or ecarpe on crest: Yes ~ N/A <br />4. Cracks or ecarpe on elope: Yes ® N/A <br />5. Sloughing or bulging on slope: Yes ® N/A <br />6. *Major erosion problems: Yee ® N/A <br />7. Surface movements in valley bottom or on hillside: Yes ® N/A <br />8. *Eroeion of toe: Yee ® N/A <br />9. *Water impounded against downstream toe: Yee !~ N/A <br />10. Existing embankment freeboard: Annr~ximately 1.5 feet <br />11. Increase Decrease in water level: No chang e feet <br />12. Cracks, bulging, or erosion on upstream face: Yes ~ N/A <br />13. Spillway erosion: Yee ~ N/A <br />14. *clogging <br /> Spillway channels: Yes N/A <br /> D ivereion ditches: Yee N/A <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse <br />conditions noted in these items should normally be described (extent, location, volume, <br />etc.) in the apace on the back of this sheet. <br />