ACZ Laboratories, Inc. <br />'Batch A distinct set of samples analyzetl at a specifc lime <br />Found Value of the QC Type of interest <br />Limit Upper limit for RPD, in %. <br />Lower Lower Recovery Limit, in % (except for LCSS, mg/Kg) <br />MDL Method Detection Limit. Same as Minimum Reporting Limit. Allows for instrument and annual fluctuations. <br />PCN/SCN A number assigned to reagents/standards to trace to the manufacturer's certificate of analysis <br />P(7L Practical Cuantitation Limit, typically 5 times [he MDL. <br />CC True Value of the Control Sample or the amount added to the Spike <br />Rec Amount of the true value or spike added recovered, in % (except far LCSS, mgMg) <br />RPD Relative Percent Difference, calculation used for Duplicate DC Types <br />Upper Upper Recovery Limit, in % (except for LCSS, mg/Kg) <br />Sample Value of the Sample of interest <br /> <br /> . <br />AS Analytical Spike (Post Digestion) LCSWD Laboratory Control Sample -Water Duplicate <br />ASD Analytical Spike (Post Digestion) Duplicate LFB Laboratory Fortified Blank <br />CCB Continuing Calibration Blank LFM Laboratory Fortifed Matrix <br />CCV Continuing Calivation Verifcation standard LFMD Laboratory Fortfied MaMx Duplicate <br />DUP Sample Duplicate LRB Laboratory Reagent Blank <br />ICB Initial Calibration Blank MS Matrix Spike <br />ICV Initial Calibration Verifcation standard MSD Matrix Spike Duplicate <br />lCSAB Inter-element Correction Standard - A plus B solutions PBS Prep Blank -Soil <br />LCSS Laboratory Control Sample -Soil PBW Prep Blank -Water <br />LCSSD Laboratory Control Sample -Soil Duplicate PQV Practical Quantitation Verifcation standard <br />LCSW Laboratory Control Sample -Water SOL Serial Dilution <br />Blanks Verifies that there is no or minimal contamination in the prep methotl or calibration procedure. <br />Control Samples Verifies the accuracy of the method. including the prep procedure. <br />Duplicates Verifies the precision of the instrument and/or method. <br />SpikeslFortifed Matrix Determines sample matrix interferences, if any. <br />Standard Verifies the validity of the calibration. <br />~ ~ . <br />B Analyte concentration detected at a value between MDL and PCL. <br />H Analysis exceeded method hold time. pH is a field test with an immediate hold time. <br />R Poor spike recovery accepted beceuse the other spike in the set tell within Iha given limits. <br />T High Relative Percent Difference (RPD) acceptetl bequse sample concentrations are less than 10x the MDL. <br />U Analyle was analyzed for but not detected al the indicated MDL <br />V High blank data accepted because sample concentration is 10 times higher than blank concentration <br />W Poor recevery for Silver quality control is accepted because Silver often precipitates with Chloride. <br />X Duality control sample is out of control. <br />Z Poor spike recovery is accepted because sample concentration is four times greater than spike concentration. <br />(1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes, March 1983. <br />(2) EPA 600/R-93-100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993. <br />(3) EPA 600/R-g4-111. Methods for the Delertnination of Metals in Environmental Samples -Supplement I, May 1994. <br />(5) EPA SW-646. Test Methods for Evaluating Solid Waste, Third Etlition with Update III, December 1996. <br />(6) Standard Methods for the Examination of Water antl Wastewater, 19th edition, 1996. <br />(1) OC results calculated from raw data. Results may vary slightly if the rounded values are used in the calculations. <br />(2) Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br />(3) Animal matrices for Inorganic analyses are reposed on an "as received" basis. <br />REPIN03.11.00.01 <br />LA3879: Page 11 of 32 <br />