Laserfiche WebLink
AC~ Laboratories, Inc. <br />2773 Downhill Dave Steamboat Springs, CO 80481 (800) 334-5493 <br />Connell Resources November 15, 2002 <br />Project: L39081 <br />~;.r„sTYC~4'~t. ~Vr~°.'a~rx ~.'s,',~~~.~~~~w.Li:{i:-d~'ryr~,..."~.sa::.1~^~'~'.~.~ `.,t`~aa._.. n"t,.,'7 <br />ACZ Laboratories, Inc. (ACZ) received 3 ground water samples from Connell Resources on October 25, 2002. The samples <br />were received in good condition. Upon receipt, the sample custodian removed the samples from the cooler, inspected the <br />contents, and logged the samples into ACZ's computerized Laboratory Information Management System (LIMB). The <br />samples were assigned ACZ LIMS project number L39081. The custodian verified the_sample information entered into the <br />computer against the chain of custody (COC) forms and sample bottle labels. <br />All analyses were performed within EPA recommended holtling times. <br />These samples were analyzed forrnorganrc, organic parameters. The individual methods are referenced on both, the ACZ <br />invoice and the analytical reports. The following anomaly was identified during the analysis of these samples: <br />1. The Oil and Grease values are estimated due to the low recovery of the LCSWD at 73.8%. The control limits are 80- <br />120%. All other OC including the LCSW were within wntrol limits. <br />2. TPH was detected in the Prep Blank (PBW) at 0.23 mg/L. This is due to solvent contamination. The TPH results are <br />flagged with a'B". <br />• <br />.0 .11.00.01 <br />L39081: Page 2 of 74 <br />