Laserfiche WebLink
PERIODIC INSPECTION FORM <br /> Seate <br />r, Sediment, or Slurry Im <br />youndmente <br />INSPECTOR \ <br />' S NAME: QeMln ~ S J o he-S h <br />DATE : "1 -a ~~ ~ ~ <br />NPDES I.D . NO.: CO-0000221 D.P. 006 <br />FACILITY CONFIGURATION: Cross-Valley Pond DATE LAST INSPECTION: 6 ~~ l-~ <br />SITE NAME : Pond #006/Pre-Settling Basin LOCATION: NW'/a NW'1a Sec. 22 TSN, R88W <br />MINE NAME : Seneca II-W Mine (Seneca Coal Co I LOCATION: B mi S of Hayden, CO <br />MINE I.D. NO.: CMLRD Permit No. C- 82-057 OWNER'S REP.: Greag Hitchen Gen Mar <br />Circle or write in aoyroyriate resoonea <br />1. Foundation preparation (removal of vegetation, stumps, topsoil: Yes No N/A <br />2. Lift thickness: 12 in. N/A <br />3. Compaction according to approved plan: Yes No N/A <br />4. Burning (specify extent and location): Yes No N/A <br />5. Angle of slope: 3:1 upstream, 3:1 downstream Total = 6:1 N/A <br />6. *Seepage (specify location, color, and approximate volume) <br /> From underdrain pipes: Yes No NL <br /> At isolated points on embankment slopes: Yes o N/A <br /> At natural hillside: Yes No N/A <br /> Over widespread areas: Yes No N/A <br /> From downstream foundation area: Yes No N/A <br /> "Boils" beneath stream or ponded water: Yes No N/A <br />7. Cracks or scarps on crest: Yes No N/A <br />8. Cracks or scarps on slope: Yes No N/A <br />9. Sloughing or bulging on slope: Yes No N/A <br />10. *Major erosion problems: Yes No N/A <br />11. Surface movements in valley bottom or on hillside: Yes No N/A <br />12. *Erosion of toe: Yes No N/A <br />13. *Water impounded against toe: Yes No N/A <br />19. Existing embankment freeboard: (normal = 8.5') ~ feet <br />15. X Increase ~ Decrease in water level: ~• ~ feet <br />16. Cracks, bul in pstream face: <br />g g, or erosion on u Yes No N/A <br />17. Visible sumps or sinkholes in slurry surface: Yes No <br />18. *Clogging <br /> Spillway channels and pipes: Yes ~ N/A <br /> Decant system: Yes No NL <br /> Diversion ditches: Yes ~ N/A <br />19. *Cracking or crushing of pipes <br /> Spillway pipes: Yes ~ N/A <br /> Decant system: Yes No <br />20. Trash racks clear and in place: Y s No N/A <br />*Major adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />