My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PERMFILE62830
DRMS
>
Back File Migration
>
Permit File
>
700000
>
PERMFILE62830
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 11:09:06 PM
Creation date
11/20/2007 7:43:34 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083A
IBM Index Class Name
Permit File
Doc Date
12/11/2001
Section_Exhibit Name
Exhibit 11 Colorado Discharge Permit - NPDES
Media Type
D
Archive
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C~ <br />C. DEFIlYITIONS OF TERMS <br />PART I <br />Page No. 11 <br />Permit No. CO-0044776 <br />if t_he c_ampline frequency is more frequent than mon~h!v: Eliminate the result of TNTC from any further <br />calculations, and use all the othec results obtained within that month for reporting purposes. Attach a letter <br />noting that a result of TNTC was obtained, and list ail individual analytical results and corresponding sampling <br />dales for that month. <br />Additional relevant definitions aze found in the Colorado Water Quality Control Act, CRS §§ 25-8-101 gt seo.., <br />the Retulations for the Crate I?iccharpg Permit Svctem, 5 CCR 1002-2, § 61.0 Sl Sgq and other applicable <br />regulations. <br />D. SPECIAL REQUIREMENTS <br />1. Materials Containment Plan <br />Pursuant to Sections 61.8(3)(8) and (r) of the Colorado Dischazge Permit System Regulations, the permittee is <br />required to submit a Materials Containment Plan. Such a plan shall be submitted to the Division within ninety days <br />aher the effective date of this permit and must be implemented. The plan shall include information and procedures <br />for the prevention and containment of spills of materials used, processed or stored at the facility which if spilled <br />would have a reasonable probability of having a visible or otherwise detrimental impact on waters of the State Uy. <br />The plan shall include, but not necessarily be limited to: <br />a. A history of the spills which have occurred in the three years preceding the effective date of this permit. The <br />history shall include a discussion on the cause of the spills and the preventative measures designed to eliminate <br />them from reoccurring; <br />b. A description of the reporting system which will be used [o notify, at a minimum, responsible facility <br />management, the Division, the Environmental Protection Agency, downstream water users within 5 miles <br />downstream of the facility, and local health officials; <br />c. A description of preventative facilities (including overall facility plot) which prevent, contain, or treat spills and <br />unplanned discharges; <br />d. A list which includes the volumes or quantities of all materials used, processed, or stored at the facility w[tich <br />represent a potential spill threat to surface waters. The location of stared material shall be indicated on the <br />facility plot submitted for item c; <br />e. An implementation schedule for additional facilities which might be required in item c, but whicfi are not yet <br />operational; <br />f. A list of available outside contractors, agencies, or other sources which could be utilized in dte event of a spill <br />in order to clean up its effects. If [he facility is capable of handling spills in-house, this shall be docttmented in <br />the plan; <br />g. Provision for yearly review and updating of the contingency plan, plus resubmission of the plan to the Division <br />if conditions and/or procedures at the facility change the original plan. <br />The foregoing provisions shall in no way render inapplicable those requirements imposed by the Federal Water <br />Pollurion Control Act, 33 U.S.C. § 1321, regulations promulgated thereunder, the Colorado Water Quality Control <br />Act, and regulations promulgated thereunder. It is recommended tha[ this plan be prepared by a professional <br />engineer registered in the State of Colorado. <br />
The URL can be used to link to this page
Your browser does not support the video tag.