Laserfiche WebLink
<br />PERIODIC INSPECTION FORM <br />Stockponds or Sumps <br />INSPECTOR'S NAME: Tom Wainwrioht DATE: 06/8/94 <br />FACILITY CONFIGURATION: Stockpond DATE LAST INSPECTION: 3/30/94 <br />SITE NAME: T-1 SITE LOCATION: SE~SW'., Sec 2, TSN, R87W <br />MINE NAME: Seneca II LOCATION: 7.1 mi SE of Havden, Colorado <br />MINE I.D. NO.: C-80-005 OWNER'S REP.: Scott Williams, Supt. <br />Circle or write in appropriate response <br />1. Angle of slope: 3:1 upstream, 4:1 downstream Total = 7_1 N/A <br />2. *Seepage (specify location, color, and approximate volume) <br /> At isolated points on embankment slopes: Yes ~~ N/A <br /> At natural hillside: Yes ® N/A <br /> Over widespread areas: Yes No N/A <br /> From downstream foundation area: Yes ~ N/A <br /> "Boils" beneath stream or ponded water: Yes ~ N/A <br />3. Cracks or scarps on crest: Yes ~ N/A <br />4. Cracks or scarps on slope: Yes ~ N/A <br />5. Sloughing or bulging on slope: Yes 'o N/A <br />6. "Major erosion problems: Yes No N/A <br />7. Surface movements in valley bottom or on hillside: Yes ~io N/A <br />8. *Erosion of toe: Yes ~ N/A <br />9. *Water impounded against downstream toe: Yes No N/A <br />10. Existing embankment freeboard: from crest 1 feet (approx) <br />11. X Increase Decrease in water level: Approx. .5 feet <br />12. Cracks, bulging, or erosion on upstream face: Yes ~ N/A <br />13. Spillway erosion: es No N/A <br />14. *Clogging <br /> Spillway channels: Yes ~ N A <br /> Diversion ditches: Yes No <br />Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions <br />noted in these items should normally be described (extent, location, volume, etc.) in the <br />space on the back of this sheet. <br />