Laserfiche WebLink
PERIODIC INSPECTION FORM <br />Water, Sediment, or Slurry Impoundments <br />INSPECTOR' S NAME: Michael Altavilla DATE: 09 /18/96 <br />NPDES I.D. NO.: CO-0000221 D.P. 009 <br />FACILITY CONFIGURATION: Cross-Valley Pond DATE LAST INSPECTION: 06/05 /96 <br />SITE NAME: Pond #009 LOCATION: SES: SWS:. Sec. 11. TSN. R88W <br />MINE NAME: Seneca II-W Mine (Seneca Coal Co) LOCATION: 8 mi. S of Hayden. CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S RE P.: Brad Brown. Gen Mar <br />Circle or write in appropriate response <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7. <br />S. <br />9. <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16 <br />17 <br />18 <br />19 <br />20 <br />Foundation preparation (removal of vegetation, stumps, topsoil: es No N/A <br />Lift thickness: 12 in. N/A <br />Compaction according to approved plan: _ _-.,_ ~ No N/A <br />Burning (specify extent and location): Yes No /A <br />Angle of slope: 3:1 upstream, 3:1 downstream Total = 6:1 N/A <br />*Seepage (specify location, color, and approximate volume) <br />From underdrain pipes: Yes No / <br />At isolated points on embankment slopes: Yes N A <br />At natural hillside: Yes o N/A <br />Over widespread areas: Yes N/A <br />From downstream foundation area: Yes N/A <br />"Boils" beneath stream or ponded water: Yes ~ N/A <br />Crac::= cr scarps on crest: Yes ® :d,A <br />Cracks or scarps on slope: Yes ® N/A <br />Sloughing or bulging on slope: Yes ® N/A <br />•Maj or erosion problems: Yes N/A <br />Surface movements in valley bottom or on hillside: Yes N/A <br />Erosion of toe: Yes N/A <br />*Water impounded against toe: Yes o N/A <br />Existing embankment freeboard: Approximately 9.9 feet <br />Increase X Decrease in water level: 3.0 feet <br />Cracks, bulging, or erosion on upstream face: Yes ~ N/A <br />Visible sumps or sinkholes in slurry surface: Yes No <br />Clogging <br /> <br />Spillway channels and pipes: <br />Yes ~~ <br />~moJ <br />N A <br />Decant system: ~ Yea o <br />Diversion ditches: Yes No A <br />'Cracking or crushing of pipes <br />Spillway pipes: Yes ~ I~„~ <br />Decant system: Yes No ~~7/7~J <br />Trash racks clear and in place: ~ No N/A <br />+Maj or adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions <br />noted in these items should normally be described (extent, location, volume, etc.) in the <br />space on the back of this sheet. <br />