My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO26851
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO26851
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:46:18 PM
Creation date
11/20/2007 7:12:15 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Hydrology
Doc Date
12/21/2005
Doc Name
WO # 05-11-113
From
Paragon Analytics
To
CEMEX Inc.
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
different than those in the ICV, and a readback of the highest calibration <br />standazd. <br />These solutions provide verification that the calibration equations are <br />functioning properly throughout the analytical range of the instrument. During <br />sample analysis dilutions are made for analytes found at concentrations above <br />the highest calibration standard. No results are taken from extrapolations <br />beyond the highest standard. <br />6. All standards and solutions are NIST traceable and were used within their <br />recommended shelf life. <br />7. The samples were prepazed and analyzed within the established hold times. <br />All in house quality control procedures were followed, as described below. <br />8. General quality control procedures. <br />^ A filter (method) blank and laboratory control sample were filtered and <br />preserved at the same time as the samples for the selenium batch. A filter <br />(method) blank was filtered and preserved at the same time as the samples for <br />the thallium batch. There were not more than 20 samples associated with each <br />filtered blank and laboratory control sample. <br />^ The preparation (method) blank associated with each preparation batch was <br />below the practical quantitation limit for each requested analyte. <br />^ The laboratory control sample associated with each prepazation batch was <br />within the acceptance limits. <br />r All initial and continuing calibration blanks associated with each analytical <br />batch were below the practical quantitation limits for the requested analytes. <br />^ All initial and continuing calibration verifications associated with each <br />analytical batch were within the acceptance criteria for the requested analytes. <br />This indicates a valid calibration and stable instrument conditions. <br />^ The interference check samples associated with Method 200.8 were analyzed. <br />9. Matrix specific quality control procedures. <br />Per method requirements, matrix QC was performed for each analysis. Since a <br />sample from this order number was not the selected quality control (QC) sample, <br />matrix specific QC results are not included in this report. <br />10. It is a standard PA practice that samples for ICP-MS aze analyzed at a dilution. <br />PA sample ID 051 1113-2 required a dilution to bring selenium and thallium into <br />the analytical range of the ICP-MS. <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.