Laserfiche WebLink
PERIODIC INSPECTION FORM <br /> Water, Sediment, or Slurry Impou <br />ndme <br />nts <br />' g <br />[ <br />3 ~ <br />~~ <br />INSPECTOR S NAME: Dennis Jones DATE: <br />4 <br />~+ <br />NPDES I.D. NO.: CO-0000221 D.P. 005 <br />FACILITY CONFIGURATION: Cross-Vallev Pond DATE LAST INSPECTION: I~ b~ <br />SITE NAME: Pond tk005 LOCATION: NW`/, SW~/. Sec. 10, TSN R88W <br />MINE NAME: Seneca II-W Mine (Seneca Coal Co ) LOCATION: 8 mi. S of Havden, CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S REP.: Gr ~g Kitchen, Gen Mar <br />ClrCle Or Wrlte In apprODrlate reaDOnae <br />1. Foundation preparation (removal of vegetation, stumps, topsoil: Yes <br />2. Lift thickness: 12 in. <br />3. Compaction according to approved plan: Yes <br />4. Burning (specify extent and location): No <br />5. Angle of slope: 3.5:1 upstream, 2.5:1 downstream Total = 6:1 <br />6. *Seepage (specify location, color, and approximate volume) <br /> From underdrain pipes: Yes o N/A <br /> At isolated points on embankment slopes: Yes No N/A <br /> At natural hillside: Yes No N/A <br /> Over widespread areas: Yes No N/A <br /> From downstream foundation area: Yes No N/A <br /> "Boils" beneath stream or ponded water: Yes No N/A <br />7. Cracks or scarps on crest: Yes No N/A <br />8. Cracks or scarps on slope: Yes No N/A <br />9. Sloughing or bulging on slope: Yes N N/A <br />10. *Maj or erosion problems: Yes N N/A <br />11. Surface movements in valley bottom or on hillside: Yes No N/A <br />12. *Erosion of toe: Yes No N/A <br />13. *Water impounded against toe: Y <br />e <br />s N/A <br />14. Existing embankment freeboard: (normal = 7.4') ~~ <br />~ <br />~ <br />~-1--L feet <br />15. Increase _~ Decrease in water level: 3_._._ feet <br />16. Cracks, bulging, or erosion on upstream face: Yes ~ N/A <br />17. visible sumps or sinkholes in slurry surface: NSA <br />18. *Clogging <br /> Spillway channels and pipes: Yes No N/A <br /> Decant system: Yes No N/A <br /> Diversion ditches: <br />19. *Cracking or crushing of pipes <br /> Spillway pipes: Yes NO N/A <br /> Decant system: Yes No N/A <br />20. Trash racks clear and in place: Yes No N/A <br />*Maj or adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />