Laserfiche WebLink
SOP #: GW 0001 <br />Region I Low Stress <br />(Low Flow) SOP <br />Revision Number: 2 <br />Date; July 30, 1996 <br />Page 11 of 13 <br />detection method. <br />Pumping rate, drawdown, indicator parameters values, and clock <br />time, at the appropriate time intervals; calculated or measured <br />total volume pumped. <br />Well sampling sequence and time of each sample collection. <br />Types of sample bottles used and sample identification numbers. <br />Preservatives used. <br />Parameters requested for analysis. <br />Field observations during sampling event. <br />Name of sample collector(s). <br />Weather conditions. <br />~ QA/QC data for field instruments. <br />' Any problems encountered should be highlighted. <br />Description of all sampling equipment used, including trade names, <br />model number, diameters, material composition, etc. <br />VIII. DATA REPORT <br />Data reports are to include laboratory analytical results, QA/QC <br />information, and whatever field logbook information is needed to <br />allow for a full evaluation of data useability. <br />