Parameter
<br />Aluminum, total
<br />~ Aluminum, dissolved
<br />Beryllium, total
<br />Beryllium, dissolved
<br />Cadmium, total
<br />Cadmium, dissolved
<br />Chromium, total
<br />Chromium, dissolved
<br />Ch romium,(hexavalent)
<br />total
<br />Chromium,(hexavalent),
<br />dissolved
<br />Copper, total
<br />Copper, dissolved
<br />Iron, total
<br />Iron, dissolved
<br />Lead, total
<br />Lead, dissolved
<br />t•tanganese, total
<br />htanganese, dissolved
<br />Mercury, total
<br />t•iercury, dissolved
<br />Nickel, total
<br />Nickel, dissolved
<br />Selenium, total
<br />Selenium, dissolved
<br />• Silver, total
<br />~ Silver, dissolved
<br />Uranium, total
<br />Uranium, dissolved
<br />Thallium, total
<br />Thallium, dissolved
<br />Zinc, total
<br />Zinc, dissolved
<br />Barium, total
<br />Barium, dissolved
<br />Boron, total
<br />Boron, dissolved
<br />Arsenic, total
<br />Arsenic, dissolved
<br />Table No. 1
<br />^
<br />r
<br />~~ m9/1
<br />.
<br />,..-
<br />Above Allen Below Allen Allen Mine
<br />Mine Mine il. Fork
<br />0.22 0.11 <0.08
<br /><0.08 <0.08 <0.08
<br /><0.004 <0.004 <0.004
<br /><0.004 <0.009 <0.004
<br />X0.009 <0.009 <0.009
<br /><0.009 <0.009 <0.009
<br />0.013 0.21 0.19
<br /><0.006 <0.006 <0.006
<br /><0.006 <0.006 <0.006
<br /><0.006 <0.006 <0.006
<br /><0.005 <0.005 <0.005
<br /><0.005 <0.005 <0.005
<br />0.09 0.09 0.13
<br />0.03 0.02 0.02
<br /><0.05 <0.05 <0.05
<br /><0.05 <0.05 <0.06
<br />0.022 0.024 0.015
<br />0.007 0.007 0.008
<br />0.0002 0.0003 0.00008
<br />0.0001 <0.0001 0.0005
<br />0.02 0.04 0.02
<br />0.04 <0.01 <0.01
<br /><0.001 <0.001 <0.001
<br /><0.001 <0.001 X0.001
<br />0.017 0.017 0.015
<br /><0.004 <0.004 <0.004
<br /><0.001 0.001 <0.001
<br />0.001 <0.001 0.001
<br /><0.05 X0.05 <0.05
<br />X0.05 <0.05 <0.05
<br />0.048 0.098 0.060
<br />0.010 0.020 0.011
<br />0.3 <0.1 <0.1
<br /><0.1 <0.1 <0.1
<br />0.37 0.32 0.26
<br />0.20 0.21 0.36
<br /><0.002 <0.002 <0.002
<br /><0.002 <0.002 <0.002
<br />Note: These samples will be reanalyzed for lead, Cadmium, and Silver by graphite
<br />furnace atomic absorption to obtain a lower detection level, as per phone conversation -
<br />between Bruce Hale and J. Gillespie, November 24, 1980.
<br />If there are any questions concerning these results, please call.
<br />~ ~ /~ .
<br />• Bruce A. Hale M. L. ~ c Ph.D., ''anaaer
<br />~ Secticn Supervisor Instrument Analysis Div.
<br />COMMERCIAL TESTING & ENGINEERING CO.
<br />Ongina~ Coov ~Varermar4ea
<br />For your vrocea.on
<br />F .d 6fi