Laserfiche WebLink
ACZ Laboratories, Inc. <br />~~za n„w~nat nd,.P SleamMat s,,.;.,~< cn ROdR] /ROnI Tl <br />Batch A distinct set of samples analyzed at a specific time <br />Found Value of the DC Type of interest <br />Limit Upper limit for RPD, in %. <br />Lower Lower Recovery Limit, in % (except for LCSS, mg/Kg) <br />MDL Method Detection Limit. Same as Minimum Reporting Limit. Allows for instrument and annual fluctuations. <br />PCN/SCN A number assigned to reagents/standartls to trace to the manufacturer's certifcafe of analysis <br />PQL Practical Quantitation Limit, typically 5 times the MDL. <br />QC True Value of the Control Sample or the amount added to the Spike <br />Rec Amount of the true value or spike added recovered, in % (except for LCSS, mg/Kg) <br />RPD Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Upper Recovery Limit, in % (except for LCSS, mg/Kg) <br />Sample Value of the Sample of interest <br />AS Analytical Spike (Post Digestion) LCSWD laboratory Control Sample -Water Duplicate <br />ASD Analytical Spike (Post Digestion) Duplicate LFB Laboratory Fortified Blank <br />CCB Continuing Calibration Blank LFM Laboratory Fortifed Matrix <br />CGV Continuing Calivation Verifcation stantlard LFMD Laboratory Fortifietl Matdx Duplicate <br />DUP Sample Duplicate LRB Laboratory Reagent Blank <br />ICB Initial Calibration Blank MS Matrix Spike <br />ICV Initial Calibration Verification stantlard MSD Matrix Spike Duplicate <br />ICSAB Inter-element Correction stantlard - A plus B solutions PBS Prep Blank -Soil <br />LCSS Laboratory Control Sample -Soil PBW Prep Blank -Water <br />LCSSD Laboratory Control Sample -Soil Duplicate PQV Practical Quantitation Verifcation standartl <br />LCSW Laboratory Control Sample -Water SOL Serial Dilution <br />Blanks Verifes that there is no or minimal contamination in the prep method or calibration procedure. <br />Control Sa mples Verifies the accuracy of the method, inclutling th e prep procedure. <br />Duplicates Verifes the precision of the instrument and/or m ethod. <br />SpikeslFOrtifed Matrix Determines sample matrix interferences, if any. <br />Standard Verifes the validity of the calibration. <br />. • . <br />B Analyte concentration detectetl at a value between MDL and PDL. <br />H Analysis exceeded method hold time. pH is a feld test with an immediate hold time. <br />R Poor spike recovery accepted because the other spike in the set fell within the given limits. <br />T High Relative Percen( Difference (RPDj accepted because sample concentrations are less than tOx the MDL. <br />U Analyte was analyzed for but not detected at the indicated MDL <br />V High blank data accepted because sample concentration is 10 times higher than blank concentration <br />W Poor recovery for Silver quality wntrol is accepted because Silver often precipitates with Chloride. <br />X Duality control sample is out of control. <br />Z Poor spike recovery is accepted because sample concentration is four times greater than spike concentration. <br />(1) EPA 600/4-83-020. Methods for Chemical Analysis of Water and Wastes, March 1983. <br />(2) EPA 600/R-93-100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993. <br />(3) EPA 600/R-94-111. Methods (or the Determination of Metals in Environmental Samples -Supplement I, May 1994. <br />(5) EPA SW-846. Test Methods for Evaluating Solid Waste, Third Edition with Update III, December 1996. <br />(6) standartl Melhotls for the Examination of Water and Wastewater, 19th edition, 1995. <br />(1) QC results calculated from raw data. Results may vary slightly if the rounded values are usetl in the calculations. <br />(2) Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis. <br />(3) Animal matrices for Inorganic analyses are reported on an "as received" basis. <br />REPIN03.11.00.01 <br />L45050: Page 13 of 36 <br />