Laserfiche WebLink
COLORADO - CDPS WET TEST REPORT FORM-CHRONIC <br />PERMITTEE: Cwrus Empire Corporation CDPS NO. CO-0034142 OUTFACE: 022 <br />TYPE TEST: ROUTINE: XX ACCELERATED:- TEST SPECIES: P.prome/as <br />TEST RESULTS LETHALITY GROWTH STATISTICAL METHOD <br />Concentration with Statistical Difference >I00% >100% Steel's/Dunnett's <br />Pass/Fail Pass N/A <br />ICzs >100% >100% Bootstra <br />PasslFail Pass N/A <br />TEST T13v1E & DATE START 1235 PM 12/07/99 END 1125 AM 12/14!99 <br />DII,UTION (% EFFLUENT) <br />MEASUREMENTS CONTROL 11.5% 25% 50% 75% 100°/. <br />Da 1 % Survival 100 100 100 100 100 100 <br />Da 2 100 100 100 100 100 100 <br />Da 3 100 97.5 100 100 100 100 <br />Da 4 100 92.5 100 100 95.0 100 <br />Da 5 100 90.0 100 100 95.0 100 <br />Da 6 100 90.0 100 100 95.0 100 <br />Da 7 100 90.0 95.0 100 95.0 100 <br /> <br />7 Da Mean Wei ht 0.582 0.536 0.543 0675 0.577 0.609 <br /> <br />H imum/Minimum 8.4/7.8 8.5/8.0 8.4/8.1 8.6/8.1 8.6/8.1 8.5/8.1 <br />RECEIVING WATER USED FOR DILUTION? NO TOTAL RESIDUAL CI" (mg/I): <0.1 <br />HARDNESS (mP/I): REC'V WATER: EFFLUENT: 443 RECON WATER: 117 <br />ALI{ALINR'Y(mp,[l :REC'V WATER: EFFLUENT: 568 RECON WATER: 82 <br />TOT AMMONIA (~~I): INITIAL 100%: <1.0 FINAL 100'0: <1 0 <br />WERE ALL TEST CONDITIONS IN CONFORMANCE WITH DIVISION GUIDELINES? YES <br />IF NO, LIST DEVIATIONS FROM TEST SPECIFICATIONS: <br />-~ <br />LABORATORY: COMMERCIAL TESTING & ENGINEERING ANALYST: ('~1,~,.,.:..~-u--~9 <br />4/14/99 <br />COMMERCIAL TESTING & ENGINEERING CO. <br />aq~~d cosy wu«m.nea L~G <br />For Your FrOIKtIOn <br />