PERIODIC INSPECTION FORM <br />Stockponda or Sampa <br />INSPECTOR'S NAME: Roy Karo DATE: 8/20/2002 <br />FACILITY CONFIGURATION: Stockpond DATE LAST INSPECTION: 6/20/2002 <br />SITE NAME: T-13 LOCATION: NW'~iSE;'., Sec 12, T5N, R87W <br />MZNE NAME: Seneca II LOCATION: 7.1 mi SE of Hayden, CO <br />MINE I.D. NO.: C-60-005 OWNER'S REP.: Gregg Kitchen <br />Circle or xri to in appropriate response <br />1. Angle of slope: 3:1 upstream, 3:1 downstream Total = 6:1 N/A <br />2. *Seepage (specify location, color, and approximate volume) <br /> At isolated points on embankment slopes: Yes N/A <br /> At natural hillside: Yes N/A <br /> Over widespread areas: Yes N/A <br /> From downstream foundation area: Yes N/A <br /> "Boils" beneath stream or ponded water: Yes N/A <br />3. Cracks or scarps on crest: Yes N/A <br />9. Cracks or scarps on slope: Yes N/A <br />5. Sloughing or bulging on slope: Yes N/A <br />6. *Major erosion problems: Yes N/A <br />7. Surface movements in valley bottom or on hillside: Yes N/A <br />8. *Erosion of toe: Yes N/A <br />9. *Water impounded against downstream toe: Ye N/A <br />10. Existing embankment freeboard: Approximately ~~ et <br />11. Increase Decrease in wa ter level: No change feet <br />12. Cracks, bulging, or erosion on upstream face: Yes o N/A <br />13. Spillway erosion: Yes N/A <br />19. *Clogging <br />Spillway channels: Yes N/A <br />Diversion ditches: Yes N/A <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse <br />conditions noted in these items should normally be described (extent, location, volume, <br />etc.) in the space on the back of this sheet. <br />~~~ ~~ G X11 <br />~~ <br />