Laserfiche WebLink
PERIODIC INSPECTION FORM <br /> Water, Sediment, or Slurry Impou <br />ndments <br />INSPECTOR 'S NAME: Dennis Jones nf <br />DATE: ~O'n6'U~ <br /> <br />D <br />D <br />P <br />G <br />OO <br />D <br />05 ~j 7 ~/ <br />~~ <br />FA <br />CILITY CON <br />IGURAT <br />I ON <br />Cross <br />Vallev <br />Pond DATE LAST INSPECTION: IS - J 0 <br />SITE NAME : Pond #005 LOCATION: N4dl SW~/,, Sec. 10, TSN, R88W <br />MINE NAME : Seneca II-W Mine (Seneca Coal Co ) LOCATION: 8 mi. S of Hayden, CO <br />MINE I.D. NO.: CMLRD Permit No. C-82-057 OWNER'S REP.: Gregg Kitchen. Gen Mgr <br />Circle or write in appropriate reaoonae <br />1. Foundation preparation (removal of vegetation, stumps, topsoil: Yes <br />2. Lift thickness: 12 in. <br />3. Compaction according to approved plan: Yes <br />4. Burning (specify extent and location): No <br />5. Angle of slope: 3.5:1 upstream, 2.5:1 downstream Total = 6:1 <br />6. *Seepage (specify location, color, and approximate volume) <br /> From underdrain pipes: Yes o N/A <br /> At isolated points on embankment slopes: Yes No N/A <br /> At natural hillside: Yes No N/A <br /> Over widespread areas: Yes No N/A <br /> From downstream foundation area: Yes No N/A <br /> "Boils" beneath stream or ponded water: Yes No N/A <br />7. Cracks or scarps on crest: Yes No N/A <br />8. Cracks or scarps on slope: Yes No N/A <br />9. Sloughing or bulging on slope: ~ Yes o N/A <br />10. *Major erosion problems: Yes o N/A <br />11. Surface movements in valley bottom or on hillside: Yes No N/A <br />12. *Erosion o£ toe: Yes No N/A <br />13. *Water impounded against toe: Yes N/A <br />14. Existing embankment freeboard: (normal = 7.4') ~ feet <br />15. Increase 1C Decrease in water level: !.O feet <br />16. Cracks, bulging, or erosion on upstream face: Yes ~ N/A <br />17. Visible sumps or sinkholes in slurry surface: NL <br />18. *Clogging <br /> Spillway channels and pipes: Yes No N/A <br /> Decant system: Yes No N/A <br /> Diversion ditches: <br />19. *Cracking or crushing of pipes <br /> Spillway pipes: Yes No N/A <br /> Decant system: Yes No N/A <br />20. Trash racks clear and in place: es No N/A <br />*Major adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br /> <br />