Laserfiche WebLink
PERIODIC INSPECTION PORN <br />6tockponds or bumps <br />INSPECTOR'S NAME: Rov Rare DATE: ]215/96 <br />FACILITY CONFIGURATION: ate ~nnd DATE LAST INSPECTION: 09/28/98 <br />SITE NAME: T-4 LOCATION: RW~.NF'g a`P_C 11 TSN~RB7W <br />MINE NAME: Seneca II LOCATION: 7.t m+ S. o Hayde ~" CO <br />MINE I.D. NO.: C-80-DOS OWNER'S REP.: Brad Brown_ Gen Mar <br />1. Angle of elope: 3e1 upstream, 2.set downstream Total = 5.5:~ N/A <br />2. *Seepage (specify location, color, and approximate volume) <br /> At isolated points on embankment slopes: Yee No N/A <br /> At natural hillside: Yee No N/A <br /> Over widespread areas: Yee No N/A <br /> From downstream foundation area: Yee No N/A <br /> "Boils" beneath stream or ponded water: Yee No N/A <br />3. Cracks or scarps on treat: Yee No N/A <br />4. Cracks or scarps on elope: Yee No N/A <br />5. Sloughing or bulging on elope: Yee No N/A <br />6. *Major erosion problems: Yea No N/A <br />7. Surface movements in valley bottom or on hillside: Yes No N/A <br />8. *Erosion of toe: Yee No N/A <br />9. *Water impounded against downstream toe: Yee No N/A <br />10. Existing embankment freeboard: App7-ox~ may -3 feet <br />11. Increase Decrease in water level: No chang e feet <br />12. Cracks, bulging, or erosion on upstream face: Yee No N/A <br />13. Spillway erosion: Yee No N/A <br />14. "Clogging <br /> Spillway channels: Yea No N/A <br /> Diversion ditches: Yea No N/A <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manaqer and Mine Superintendent for further evaluation. Adverse <br />conditions noted in these items should normally be described (extent, location, volume, <br />etc.) in the apace on the back of this sheet. <br />