Laserfiche WebLink
~~~ <br />~~ <br />' nDDRESS AtI CORRESPONDENCE TO~ <br />r,nMMF r-~~~,:,1 it°`. ^r:~.dENG1NEER11N3 C0 <br />.~ -'~ ~"~+~a5 STREET, SUITE 82(X1 <br />COLORADO -CDPS WET TEST REPORT FORM -ACUTE D EivEa~ca>':+~in <br />FA% i323) 373~~7°7 <br />PERMITTEE: Seneca Coal Company CDPS NO.: CO-0000221 OUTFACE: 016 <br />TYPE TEST: ROUTINE: XX ACCELERATED: _ SPECIES: P. nromelas <br />TEST RESULTS: LC,~: >100"/° STATISTICAL METHOD: Binomial <br />TEST TIME & DATE: BEGIN: 1240 PM 05120!03 END: 112 5 AP~1 05/24103 <br /> <br /> DILUTIONS (% EFFLUENT) <br />MEASUREMENTS 0% 12.5% 25% 50% 75% 100% <br /># a START OF TEST: 40 40 40 40 40 40 <br /># ALIVE AFTER 24 HRS: 40 40 40 40 40 40 <br /># ALIVE AFTER 48 HRS: 40 40 40 40 40 40 <br /># ALIVE AFTER 72 HRS: 40 40 40 40 40 40 <br /># ALIVE AFTER 96 HRS: 40 40 40 40 40 40 <br />RECEIVING WATER USED FOR DILUTION? NO TOTAL RESIDUAL CI (mgA): <0.1 <br />HARDNESS (mg/l): RECEIVING WATER: EFFLUENT: 1230 RECON WATER: 120 <br />ALKALINITY (mg/l): RECEIVING WATER: EFFLUENT: 250 RECON WATER: 90 <br />pH INITIAL: CONTROL 8.3 100% EFFLUENT 8.3 <br />FINAL: CONTROL 8.2 100% EFFLUENT 8.2 <br />TOTAL AMMONIA AS N (mg/l): INITIAL 100%: =5.0 FINAL 100%: .4.0 <br />WERE ALL TEST CONDITIONS IN CONFORMANCE WITH DIVISION GUIDELINES? YES <br />IF NO, LIST DEVIATIONS FROM TEST SPECIFICATIONS: <br />LABORATORY: SGS COMMERCIAL TESTING 8 ENGINEERING ANALYST: C~<<`~~ <br />COMMENTS: <br />04/08/03 <br /> <br />