My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO24065
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO24065
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:44:17 PM
Creation date
11/20/2007 4:19:07 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977208
IBM Index Class Name
Hydrology
Doc Date
11/16/2005
Doc Name
Water Sample Results and Level
From
CEMEX Inc.
To
DMG
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
middle of the analytical range, a Continuing Calibration Verification (CCV) <br />standazd with concentrations near the middle of the analytical range but <br />different than those in the ICV, and a readback of the highest calibration <br />standard. <br />These solutions provide verification that the cahbration equations are <br />functioning properly throughout the analytical range of the instrument. During <br />sample analysis dilutions are made for analytes found at concentrations above <br />the highest calibration standard. No results are taken from extrapolations <br />beyond the highest standazd. <br />6. All standards and solutions are NISI traceable and were used within their <br />recommended shelf life. <br />7. The samples were prepazed and analyzed within the established hold times. <br />All in house quality control pmcedures were followed, as described below. <br />8. Genera] quality control procedures. <br />^ A filter (method) blank and laboratory control sample were filtered, preserved <br />and prepared at the same time as the samples. There were not more than 20 <br />samples associated with each filtered blank and laboratory control sample. The <br />laboratory control sample was only prepared for the selenium analysis. <br />^ The preparation (method) blank associated with each batch was below the <br />practical quantization limit for each requested analyte. <br />^ The laboratory control sample associated with the selenium batch was within <br />the acceptance limits. <br />^ All initial and continuing calibration blanks associated with each analytical <br />batch were below the practical quantitation limits for the requested analytes. <br />^ All initial and continuing calibration verifications associated with each <br />analytical batch were within the acceptance criteria for the requested analyzes. <br />This indicates a valid cahbration and stable instrument conditions. <br />^ The interference check samples associated with Method 200.8 were analyzed. <br />9. Matrix specific quality control procedures. <br />Per method requirements, matrix QC was performed for this analysis. Since a <br />sample from this order number was not the selected quality control (QC) sample, <br />matrix specific QC results are not included in this report. <br />10. It is a standazd PA practice that samples for ICP-MS are analyzed at a dilution. <br />Sample 0509241-2 required additional dilutions to bring selenium and thallium into <br />the analytical range ofthe ICP-MS. <br />
The URL can be used to link to this page
Your browser does not support the video tag.