Laserfiche WebLink
Appendix H Page 2 <br />C2tTiiQ~ MxC~ ~SS.~~"C~X~~S <br />• CONSULTING GEOTECHNICAL ENGINEERS AND MATERIAL TESTING <br />J.E. Stover and Associates <br />2768 Compass Drive Suite 101 <br />Grand Junction, Colorado 81506 <br />Attention: Mr. Jim Stover, P.E. <br />Subject: Laboratory Test Results for <br />McClain Canyon Mine near <br />Loma, Colorado <br />Mr. Stover: <br />November 28, 2001 <br />PN: M01246MT <br />This letter presents the results of the laboratory tests performed <br />for your McClain Canyon Mine project. The laboratory tests were <br />conducted on a coal gob sample delivered to our laboratory on October <br />17, 2001. The laboratory tests consisted of a moisture content-dry <br />density relationship test and a remolded triaxial compression strength <br />• test. <br />Moisture content-dry density relationship test was conducted on the <br />coal gob sample delivered to our laboratory. The moisture content-dry <br />density relationship test was conducted in accordance with ASTM Test <br />Method D698. The results of the moisture content-dry density <br />relationship tests are presented on Figure 1. The moisture content- <br />' dry density relationship test indicated an optimum moisture content of <br />17.0 percent and a maximum dry density of 82.0 pounds per cubic foot <br />for the sample tested. <br />Triaxial compression strength properties of a remolded sample was <br />evaluated in general accordance with testing procedures defined by <br />ASTM Test Method D2850. The sample for the triaxial compression <br />strength test was remolded to about 90 percent of the maximum dry <br />density as determined by the moisture content-dry density relationship <br />test. A consolidated drained test was performed o~ the remolded <br />sample tested. During the consolidated drained tes= the sample was <br />allowed to consolidate prior to testing the sample to failure. The <br />test was performed using a strain controlled triaxial compression <br />testing machine. The confining pressures used and the type test were <br />as directed by Mr. Jim Stover, P.E. The triaxial compression strength <br />test results are presented on Figure 2. The triaxial compression <br />strength test indicates an internal angle of friction of about 33 <br />• degrees and a cohesion of about 3 pounds per squar=_ inch. <br />F. o. eox a9e9 r. o. eox coos 2i1 eooo DR. <br />GRAND JUNCTION, CO 51502 MONfROSE, CO !1102 DURANGO. CO 91J07 <br />(970) 2153505 (970) 249.2151 (970) 2593095 <br />FAx: (870) 2CH-9759 FAX: (970) 219J262 FAX: (970) X823515 <br />