My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HYDRO22356
DRMS
>
Back File Migration
>
Hydrology
>
HYDRO22356
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 8:43:26 PM
Creation date
11/20/2007 2:57:35 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1982057
IBM Index Class Name
Hydrology
Doc Date
8/26/1997
Doc Name
SENECA MINE COMPLEX NPDES PERMIT
From
SENECA COAL CO
To
DMG
Permit Index Doc Type
NPDES
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PARTI <br />Page 17 <br />Permit No. CO-0000221 <br />• D. SPECIAL REQUIItEMENTS <br />1. Materials Containment Plan <br />Pursuant [o Sections 6.9.3 (6) and (18) of the Regulazions for the State Discharge Permit System, the permittee is <br />required to submit a Materials Containment Plan. Such a plan was previously submitted to the Division. An update of <br />the plan shall be submitted to the Division within ninety (90) days after the effective date of this permit and must be <br />implemented. The update of the plan shall include changes in the information and procedures for the prevention and <br />containment of spills of materials used, processed or stored az the facility which if spilled would have a reasonable <br />probability of having a visible or otherwise detrimental impact on waters of the State !"-'. The updated plan shall <br />include, bu[ not necessarily be limited to: <br />a. An updated history of the spills which have occurred in the three (3) yeazs preceding the effective date of this <br />permit. The history shall include a discussion on Ute cause of the spills and a the preventative measures designed to <br />eliminate them Crom reoccurring; <br />b. An update of the reporting system which will be used to notify, at a minimttm, responsible facility management, the <br />Division, the Environmental Protection Agency, downstream water users wiUtin 5 miles downstream of the facility, <br />and local health officials; <br />c. A description of any changes in the preventative facilities (including overall facility plot) which prevent,.contain, or <br />treat spills and unplamed discharges; <br />d. A current list which includes the volumes or quantities of all materials used, processed, or stored at the facility <br />which represent a potential spill threat to surface waters. The location of stored material shall be indicated on the <br />facility plot submitted for item c; <br />e. An implementation schedule for additional facilities which might be required m item c, but which are not yet <br />operazional; <br />f. A current list of available ou[side contractors, agencies, or other sources which could be u[ilized in the event of a <br />spill in order [o clean up its effects. If the facility is capable of handling spills in-house, this shall be documented in <br />the plan; <br />g. Provision for yearly review and updating of the contingency plan, plus resubmission of the plan to the Division if <br />conditions and/or procedures at the facility change the original plan. <br />The foregoing provisions shall in no way render inapplicable those requiremenu imposed b}' the Federal Water Pollution <br />Control Act, 33 U.S.C. § 1321, regula[ions promulgated thereunder, the Colorado Water Quality Control Ac[, and <br />regulazions promulgated thereunder. It is recommended that this plan be prepared by a professional engineer registered <br />in [he State of Colorado. <br />Nothing herein contained shall be construed as allowing any discharge to waters of the State other than through the <br />discharge points specificall}' authorized in this permit. Nothing herein contained shall be construed as excusing any <br />liability the permittee might have, civil or criminal, for any spill. <br />The submi[tal of a Spill Prevention Control and Countermeasure Plan (SPCC Plan) as required by 40 CFR Pan 112 ma}' <br />sa[isfy all or pan of this requirement. Should additional materials ezis[ on site which are not addressed in the SPCC <br />Plan, addressing those materials as per the above is required. <br />] I If there r5 no such material present at the site, this shall he indirared in writing and submivW to the Division for review. <br />2/ If there is material pmxnt but the pennittec feels there is not a n;asonablc probabdip~ of a spill impacting wau;rs of the State. this shall be documented in <br />• writmg and subtniued to the Division for review. 'ITis documentatlan shall include; I) disunce to neatest surtace wafers, and; 2) a derailed description of <br />any swcmre which prohibits the releax of material omo the ground or inm a wnveyance rystem. <br />INDBP 4/9/93 <br />
The URL can be used to link to this page
Your browser does not support the video tag.