Laserfiche WebLink
Wyoming Fuel, 8505-087-094 <br />SUMriARY <br />Sponsor: Wyoming Fuel Company, Inc. <br />Study Director: Kurt R. Drottar <br />Teat Facility: ERT, 1716 Heath Parkway, Fort Collins, CO <br />Location of Data: ERT, 1716 Heath Parkray, Fort Collins, CO <br />Test Substance: Effluent from outfall 002B collected et en <br />unspecified time May 17, 1988 <br />Subyect: 48-hour static renewal toxicity teat, Ceriodanhnia ep. <br />Test Datee: Hay 18 (14:00) to hey 20 (14:00), 1988 <br />Length of Study: 48-hours <br />Test Species: Ceriodanhnia sp. <br />Source of Organisms: ERT in-house culture <br />Age of Teet Organisms: < 24 hours <br />Test Concentrations: 0 (dilution rater control), 6.25,_ 12.5, 25, <br />50, end 100 percent effluent <br />Dilution Water: Reconstituted rater <br />Results: 48-hour LC50 > 100 percent effluent, acute NDEC = 100 <br />percent effluent <br />2 <br />