Laserfiche WebLink
SEDCAD+ VEGETATED CHANNEL DESIGN <br />-------------------------------- <br />SENECA II CHANNEL 2 • <br />INPUT VALUES: <br />Shape TRIANGULAR <br />Discharge 1.00 cfs <br />Slope 17.30 ~ <br />Sideslopes 3.00:1 (L) 3.00:1 (R) <br />Max. Velocity 7.OO0fps <br />Material TALL FESCUE <br />Freeboard .3 ft <br />RESULTS: <br /> W/ FREEBOARD <br /> STABILITY CLASS C CAPACITY CLASS B <br />Actual Discharge 0.93 0.95 cfs <br />Depth 0.49 0.60 0.90 ft <br />Top Width 2.95 3.62 5.42 ft <br />Velocity 1.29 0.87 fps <br />Cross Sectional Area 0.72 1.09 sq ft <br />Hydraulic Radius 0.23 0.29 ft <br />Manning's n 0.182 0.310 <br />Froude Number 0.46 0.28 <br /> <br /> <br />~- IZ- ll$ <br />Revised 05/08/98 <br />